Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects.

نویسندگان

  • Anand Kumar
  • Ramon Anel
  • Eugene Bunnell
  • Kalim Habet
  • Sergio Zanotti
  • Stephanie Marshall
  • Alex Neumann
  • Amjad Ali
  • Mary Cheang
  • Clifford Kavinsky
  • Joseph E Parrillo
چکیده

OBJECTIVE Pulmonary artery occlusion pressure and central venous pressure have been considered to be reliable measures of left and right ventricular preload in patients requiring invasive hemodynamic monitoring. Studies in recent years have questioned the correlation between these estimates of ventricular filling pressures and ventricular end-diastolic volumes/cardiac performance variables in specific patient groups, but clinicians have continued to consider the relationship valid in the broader context. The objective of this study was to assess the relationship between pressure estimates of ventricular preload (pulmonary artery occlusion pressure, central venous pressure) and end-diastolic ventricular volumes/cardiac performance in healthy volunteers. DESIGN Prospective, nonrandomized, nonblinded interventional study. SETTING Cardiac catheterization and echocardiography laboratories. SUBJECTS Normal healthy volunteers (n = 12 group 1, n = 32 group 2). INTERVENTIONS Pulmonary catheterization and radionuclide cineangiography (group 1) and volumetric echocardiography (group 2) during 3 L of normal saline infusion over 3 hrs. MEASUREMENTS AND MAIN RESULTS In group 1, the initial pulmonary artery occlusion pressure and central venous pressure did not correlate significantly with initial end-diastolic ventricular volume indexes or cardiac performance (cardiac index and stroke volume index). Changes in pulmonary artery occlusion pressure and central venous pressure following saline infusion also did not correlate with changes in end-diastolic ventricular volume indexes or cardiac performance. In contrast, initial end-diastolic ventricular volume indexes and changes in these ventricular volume indexes in response to 3 L of normal saline loading correlated well with initial stroke volume index and changes in stroke volume index, respectively. The relationship between left ventricular end-diastolic volume index and stroke volume index was confirmed in group 2 subjects using mathematically independent techniques to measure these variables. In addition, initial central venous pressure, right ventricular end-diastolic volume index, pulmonary artery occlusion pressure, and left ventricular end-diastolic volume index failed to correlate significantly with changes in cardiac performance in response to saline infusion in group 1 subjects. CONCLUSIONS Normal healthy volunteers demonstrate a lack of correlation between initial central venous pressure/pulmonary artery occlusion pressure and both end-diastolic ventricular volume indexes and stroke volume index. Similar results are found with respect to changes in these variables following volume infusion. In contrast, initial end-diastolic ventricular volume indexes and changes in end-diastolic ventricular volume indexes in response to saline loading correlate strongly with initial and postsaline loading changes in cardiac performance as measured by stroke volume index. These data suggest that the lack of correlation of these variables in specific patient groups described in other studies represents a more universal phenomenon that includes normal subjects. Neither central venous pressure nor pulmonary artery occlusion pressure appears to be a useful predictor of ventricular preload with respect to optimizing cardiac performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of increasing left ventricular filling. Pressure in patients with acute myocardial infarction.

Left ventricular performance in 19 patients with acute myocardial infarction has been evaluated by measuring left ventricular response in terms of cardiac output, stroke volume, work, and power to progressive elevation of filling pressure accomplished by progressive expansion of blood volume with rapid infusion of low molecular weight dextran. Such infusion can elevate the cardiac output, strok...

متن کامل

Hemodynamic parameters to guide fluid therapy

The clinical determination of the intravascular volume can be extremely difficult in critically ill and injured patients as well as those undergoing major surgery. This is problematic because fluid loading is considered the first step in the resuscitation of hemodynamically unstable patients. Yet, multiple studies have demonstrated that only approximately 50% of hemodynamically unstable patient...

متن کامل

Sequential cardiorespiratory events during and after dextran-40 infusion in normal and shock patients.

Sequential measurements of cardiac output, intravascular pressures, blood gases, pH, blood volume, and oxygen consumption were made in normal subjects and patients in shock before, during, and after infusions of dextran-40. In eight normal subjects the responses were: increased central venous pressure, increased cardiac index, decreased peripheral resistance, and decreased hemoglobin concentrat...

متن کامل

Changes in vascular capacity in awake dogs in response to carotid sinus occlusion and administration of catecholamines.

Changes in cardiac filling pressure (central venous pressure) were measured following carotid occlusion and infusions of catecholamines in awake dogs while cardiac output was held constant. After carotid occlusion in dogs with vagi blocked, central venous pressure increased about 0.8 mm Hg (an estimated decrease in vascular capacity of 2.4 ml/kg). Carotid occlusion before vagal block or followi...

متن کامل

Cardiovascular changes during drainage of pericardial effusion by thoracoscopy.

BACKGROUND Cardiovascular changes during drainage of pericardial effusion are not well understood, and most studies are of systemic effects and not of right ventricular performance. Thoracoscopy is not widely used to drain pericardial effusions because of haemodynamic changes in relation to the use of single lung ventilation. PATIENTS AND METHODS We studied 16 patients undergoing partial peri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 32 3  شماره 

صفحات  -

تاریخ انتشار 2004