Performance of stacked, flow-through micropreconcentrators for portable trace detection
نویسندگان
چکیده
Improving techniques for portable trace analyte collection and pretreatment is of critical concern for security, medical, food and environmental applications. The trend has been to employ MEMS technologies to meet this need as these microfabricated devices offer advantages such as small dead volumes, low power consumption, capacity for large scale manufacture and a commensurate savings with economies of scale. In this work a prototype trace sampling system intended for use with ion mobility spectrometers is presented. The system utilizes a stack of microfabricated preconcentrator plates capable of collecting samples in a sorbent polymer at flow rates up to 30 LPM. The plates are thermally desorbed after an integration period to produce a concentrated vapor plug that is transferred to the detector for analysis. A real-time controller, FPGA and custom electronics are used to manage independent heating of up to 4 of these devices in either constant voltage or temperature modes. The preconcentrators were tested with a commercial Vapor Tracer II IMS against TNT and RDX vapors ranging in concentration from 2.6 PPT to 620 PPT under a variety of conditions. Results are presented on performance of single preconcentrators with RDX, multiple cascaded devices vs. TNT and RDX, with and without a PDMS detector inlet membrane, and to compare sorbent coated and bare devices. The system demonstrated preconcentration factors of 38 with 2.6 PPT RDX and 30 with 13 PPT TNT.
منابع مشابه
Field detection of CO and CH4 by NIR 2f modulation laser spectroscopy
A novel compact fiber-coupled NIR system based on a DFB diode laser source is employed as a portable and sensitive gas sensor for trace detection of combustion pollutant molecules. We demonstrate the performance of such an NIR gas sensor by tracing the absorption lines of CO and CH4 using 2f-WMS technique at moderate temperature of T ~ 600°C in the recuperator channel of an industrial furnace...
متن کاملA New Method for Detecting Ships in Low Size and Low Contrast Marine Images: Using Deep Stacked Extreme Learning Machines
Detecting ships in marine images is an essential problem in maritime surveillance systems. Although several types of deep neural networks have almost ubiquitously used for this purpose, but the performance of such networks greatly drops when they are exposed to low size and low contrast images which have been captured by passive monitoring systems. On the other hand factors such as sea waves, c...
متن کاملLow-cost Vector Network Analyzer for Biomedical Applications
A low-cost and portable vector network analyzer (VNA) which covered operating frequency between 1MHz to 3GHz is used for vector reflection coefficient and standing wave ratio (swr) of the various microstrip antennas. This paper presents measurements of various ultra wideband (uwb) microstrip antennas for applications in biomedical field. Selection of antenna is an important key for detection of...
متن کاملSolid Phase Extraction of Ultra Trace Amounts of Ni2+ by Dimethylglyoxime (DMG) Immobilized on Column
A column of alumina modified with sodium dodecyl sulfate (SDS) and dimethylglyoxime (DMG) was prepared for the preconcentration of trace nickel from water samples for flame atomic absorption spectrometry (FAAS) determinations. Under optimized conditions (pH=7.0; flow rate: 20 mlmin-1) nickel was retained on the column. The nickel collected on the column was eluted with 5 mL of 1 M nitric ac...
متن کاملA New Changeable Bioreactor for Detection of Organophosphate in a Flow-Through System
A flow-through biosensor consisting of a fixed bed bioreactor was employed to detect the insecticideparaoxon. Based on the inhibition of organophosphorous insecticide to the enzymatic activity of acetylcholinesterase (AChE), using paraoxon as a model compound, the condition for detection of the insecticide were optimized. The influence of enzyme loading on the packing surface was studied ...
متن کامل