Moderate Patient-Prosthesis Mismatch Has No Negative Effect on Patients’ Functional Status After Aortic Valve Replacement With CarboMedics Prosthesis

نویسندگان

  • Alireza Alizadeh-Ghavidel
  • Rasoul Azarfarin
  • Azin Alizadehasl
  • Ali Sadeghpour-Tabaei
  • Ziae Totonchi
چکیده

BACKGROUND Patient-prosthesis mismatch (PPM) after aortic valve replacement (AVR) is the subject of continuing debate in the cardiac surgery field. OBJECTIVES The aim of this study was to evaluate the frequency and severity of patient-prosthesis mismatch (PPM) and the functional status of patients undergoing aortic valve replacement (AVR) using a CarboMedics prosthesis in the mid-term follow up. PATIENTS AND METHODS We retrospectively studied 66 consecutive patients who were referred to AVR with a CarboMedics prosthesis at the Rajaie cardiovascular medical and research center, a university referral hospital in Tehran, Iran. The severity of PPM as well as clinical and echocardiographic parameters and the patients' New York heat association (NYHA) functional classification status, operative data and postoperative complications, and mortality in a mid-term (4 - 5 months) follow up period was assessed. Severe PPM was defined as the effective orifice area (EOA) indexed to the patient's body surface area (BSA) < 0.65 cm(2)/m(2) and moderate PPM was defined as the indexed effective orifice area (IEOA) between 0.65 and 0.85 cm(2)/m(2). RESULTS Of the 66 studied patients, 39 were male and 27 were female. The mean age of the patients was 43 ± 17 with a range of 6 - 76 years. Implanted sizes of the CarboMedics AV prosthesis in 22 patients were 19 and 21 mm, and in 44 patients were 23 and 25 mm. Eleven patients had moderate PPM (IEOA < 0.85 cm(2)/m(2)) and 55 of them did not have PPM (IEOA ≥ 0.85 cm(2)/m(2)). There were no statistically significant differences between the two groups in the echocardiographic trans-aortic pressure gradients (35.6 ± 19 vs. 23.2 ± 16 mmHg; P = 0.061) and the mean NYHA functional classification (1.10 ± 0.3 vs. 1.01 ± 0.10; P = 0.074) after AVR in the mid-term follow up. CONCLUSIONS Moderate PPM has no negative effect on echocardiographic trans-aortic pressure gradients or the patients' NYHA functional status after AVR with a CarboMedics prosthesis in the mid-term follow up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?

BACKGROUND The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm(2)/m(2) <indexed effective orifice area ≤ 0.85 cm(2)/m(2)) on midterm outcomes after isolated aortic valve replacement with a 17-mm St. Jude Medical Regent valve in a large series of patients, and to determine if these effects are influenced by patient confounding variables. M...

متن کامل

[Moderate patient-prosthesis mismatch has no independent effect on 30-day mortality after isolated aortic valve replacement].

INTRODUCTION AND OBJECTIVES It is still not clear whether the presence of a moderate patient-prosthesis mismatch after isolated aortic valve replacement can increase 30-day mortality. The aim of this study was to determine whether a moderate mismatch is an independent predictor of early global or cardiac mortality after aortic valve replacement. METHODS The study involved 272 adult patients (...

متن کامل

[Influence of patient-prosthesis mismatch in the octogenarian undergoing surgery for aortic valve replacement due to severe stenosis].

INTRODUCTION AND OBJECTIVES The clinical impact of patient-prosthesis mismatch on the outcome in octogenarians who undergo surgery for aortic valve replacement due to severe stenosis is unknown. Our objective was to quantify the frequency of some degree of patient-prosthesis mismatch and its impact on mortality and life quality. METHODS We analyzed all the octogenarian patients who underwent ...

متن کامل

Five-year follow-up after heart valve replacement with the CarboMedics bileaflet prosthesis.

BACKGROUND The CarboMedics valve is a relatively new, low-profile, bileaflet, mechanical prosthesis. The results of a prospective follow-up study after valve replacement with this prosthesis in a university hospital are presented. METHODS We implanted 640 CarboMedics prostheses in 583 patients in the aortic (n = 359), mitral (n = 167), or aortic and mitral positions (double valve replacement;...

متن کامل

Predictors of Left Ventricular Mass Regression Following Aortic Valve Replacement

Method Randomized selection of 100 patients, underwent aortic valve replacement with a single type of bio-prosthesis (Medtronic Mosaic) for pure aortic stenosis. The study population showed that, 25/100 (25%) patients had prosthesis-patient mismatch of a moderate degree (indexed effective orifice area (IEOA) from 0.65 cm2/m2 0.85 cm2/m2). The effect of prosthesis-patient mismatch on the postope...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016