Parametric analysis of the spatial resolution and signal-to-noise ratio in super-resolved spatiotemporally encoded (SPEN) MRI.

نویسندگان

  • Noam Ben-Eliezer
  • Yoav Shrot
  • Lucio Frydman
  • Daniel K Sodickson
چکیده

PURPOSE Spatiotemporally Encoded (SPEN) MRI is based on progressive point-by-point refocusing of the image in the spatial rather than the k-space domain through the use of frequency-swept radiofrequency pulses and quadratic phase profiles. This technique provides high robustness against frequency-offsets including B0 inhomogeneities and chemical-shift (e.g., fat/water) distortions, and can consequently perform fMRI at challenging regions such as the orbitofrontal cortex and the olfactory bulb, as well as to improve imaging near metallic implants. This work aims to establish a comprehensive framework for the implementation and super-resolved reconstruction of SPEN-based imaging, and to accurately quantify this method's spatial-resolution and signal-to-noise ratio (SNR). THEORY AND METHODS A stepwise formalism was laid-out for calculating the optimal experimental parameters for SPEN, followed by analytical analysis of the ensuing SNR and spatial-resolution versus conventional k-space encoding. Predictions were then confirmed using computer simulations and experimentally. RESULTS Our findings show that SPEN is governed by the same fundamental signal-processing principles as k-space encoding, leading to similar averaging properties, and ultimately similar spatial-resolution and SNR levels as k-space encoding. CONCLUSION Presented analysis is applicable to general multidimensional SPEN designs and provides a unified framework for the analysis of future SPEN and similar approaches based on quadratic phase encoding.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging with referenceless distortion correction and flexible regions of interest using single-shot biaxial spatiotemporally encoded MRI

Owing to its intrinsic characteristics, spatiotemporally encoded (SPEN) imaging is less sensitive to adverse effects due to field inhomogeneity in comparison with echo planar imaging, a feature highly desired for functional, diffusion, and real-time MRI. However, the quality of images obtained with SPEN MRI is still degraded by geometric distortions when field inhomogeneity exists. In this stud...

متن کامل

Functional MRI using super-resolved spatiotemporal encoding.

Recently, new ultrafast imaging sequences such as rapid acquisition by sequential excitation and refocusing (RASER) and hybrid spatiotemporal encoding (SPEN) magnetic resonance imaging (MRI) have been proposed, in which the phase encoding of conventional echo planar imaging (EPI) is replaced with a SPEN. In contrast to EPI, SPEN provides significantly higher immunity to frequency heterogeneitie...

متن کامل

Super-resolved parallel MRI by spatiotemporal encoding.

Recent studies described an "ultrafast" scanning method based on spatiotemporal (SPEN) principles. SPEN demonstrates numerous potential advantages over EPI-based alternatives, at no additional expense in experimental complexity. An important aspect that SPEN still needs to achieve for providing a competitive ultrafast MRI acquisition alternative, entails exploiting parallel imaging algorithms w...

متن کامل

Removing silicone artifacts in diffusion-weighted breast MRI by means of shift-resolved spatiotemporally encoding.

PURPOSE Evaluate the usefulness of diffusion-weighted spatiotemporally encoded (SPEN) methods to obtain apparent diffusion coefficient (ADC) maps of fibroglandular human breast tissue, in the presence of silicone implants. METHODS Seven healthy volunteers with breast augmentation were scanned at 3 Tesla (T) using customized SPEN sequences yielding separate silicone and water (1) H images in o...

متن کامل

Referenceless reconstruction of spatiotemporally encoded imaging data: principles and applications to real-time MRI.

PURPOSE Ultrafast sequences based on "Hybrid" spatiotemporal encoding (SPEN) replace echo-planar imaging's phase encoding "blips," while retaining a k-space readout acquisition. Hardware imperfections during acquisition may lead to ghosts and striped artifacts along the SPEN dimension; akin to echo-planar imaging's Nyquist ghosts, but weaker. A referenceless method to eliminate these artifacts ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 72 2  شماره 

صفحات  -

تاریخ انتشار 2014