Reversed phase-high performance liquid chromatographic method for simultaneous estimation of tolperisone hydrochloride and etodolac in a combined fixed dose oral formulations
نویسندگان
چکیده
A reversed-phase liquid chromatographic (RP-HPLC) method was developed for the simultaneous determination of tolperisone hydrochloride (TOLP) and etodolac (ETD) in a combined fixed dose oral formulation. The analysis was carried out using a phenomenax C-18, pre-packed column. A mobile phase containing a phosphate buffer (pH 5.5) : Methanol : Acetonitrile : Tri-ethylamine (40 : 40 : 20 : 1.5), with the pH adjusted to orthophosphoric acid, was pumped at a flow rate of 1.0 ml min(1) with a UV-detector and PDA detection at 257 nm. Retention time was 3.91 minutes and 6.89 minutes for TOLP and ETD, respectively. The method was validated for linearity, accuracy, precision, sensitivity, and specificity. The method showed good linearity in the range of 3 - 21 μg ml for TOLP μg / ml and 8 - 56 μg / ml for ETD. The detection limit of the proposed method was 0.16 μg / ml and 0.58 μg / ml for TOLP and ETD, respectively. The quantification limit of the proposed method was 0.51 μg / ml and 1.7 μg / ml for TOLP and ETD, respectively. The % recovery was within the range of 99.42 - 101.15 for TOLP and 98.63 - 100.94 for ETD. The percentage RSD for precision of the method was found to be less than 2%. The method was validated as per the International Conference on Harmonization (ICH) guidelines. The developed method could be applied for routine analysis of TOLP and ETD in tablet dosage form.
منابع مشابه
High Performance Liquid Chromatographic Estimation of Drotaverine Hydrochloride and Mefenamic Acid in Human Plasma
The present work describes a reverse phase HPLC method for the quantitation of drotaverine hydrochloride and mefenamic acid in human plasma. Organic solvent system used for liquid extraction composed of dichloromethane, and isopropyl alcohol in the ratio 80:20 (v/v). The compounds were separated on a Thermo BDS Hypersil C8 (25.0 cm×4.6 mm, 5 µm particle size) column in isocratic mode with a mix...
متن کاملHigh Performance Liquid Chromatographic Estimation of Drotaverine Hydrochloride and Mefenamic Acid in Human Plasma
The present work describes a reverse phase HPLC method for the quantitation of drotaverine hydrochloride and mefenamic acid in human plasma. Organic solvent system used for liquid extraction composed of dichloromethane, and isopropyl alcohol in the ratio 80:20 (v/v). The compounds were separated on a Thermo BDS Hypersil C8 (25.0 cm×4.6 mm, 5 µm particle size) column in isocratic mode with a mix...
متن کاملA Novel High Performance Liquid Chromatographic Method for Determination of Nystatin in Pharmaceutical Formulations by Box–Behnken Statistical Experiment Design
this study a novel High Performance Liquid Chromatography for the assay of nystatin in oral and vaginal tablets were optimized and validated using Box–Behnken experimental design. The method was performed in the isocratic mode on a RP-18 column (30 °C) using a mobile phase consisting of 0.05 M ammonium acetate buffer/ Methanol mixture (30:70) and a flow-rate of 1.0 ml/min. The method was valida...
متن کاملA Reversed Phase High Performance Liquid Chromatographic Method for Determination of Rapamycin
Easily degradating and various isomeric forms of rapamycin (Sirolimus) face the determination of this compound to many challenges. In this study, we developed and validated the isocratic reversed phase high performance liquid chromatographic (RP-HPLC) method for rapamycin. Separation was performed on a C8 column (MZ, 15 × 4.6 mm, 5 µm particle size) using methanol:water (80:20 v/v) as the mobil...
متن کاملA Novel High Performance Liquid Chromatographic Method for Determination of Nystatin in Pharmaceutical Formulations by Box–Behnken Statistical Experiment Design
this study a novel High Performance Liquid Chromatography for the assay of nystatin in oral and vaginal tablets were optimized and validated using Box–Behnken experimental design. The method was performed in the isocratic mode on a RP-18 column (30 °C) using a mobile phase consisting of 0.05 M ammonium acetate buffer/ Methanol mixture (30:70) and a flow-rate of 1.0 ml/min. The method was valida...
متن کامل