Subacute Right Ventricle Perforation by Pacemaker Lead Presenting with Left Hemothorax and Shock
نویسندگان
چکیده
Cardiac perforation by pacemaker is a rare but potentially fatal complication. Acute perforations occurring within twenty-four hours of insertion of pacemaker can lead to hemopericardium, cardiac tamponade, and death. Hemothorax occurring as an acute complication of pacemaker insertion is reported but extremely rare. Previously, hemothorax and shock as a subacute complication following pacemaker insertion have not been reported. We report the case of an 85-year-old patient who presented with shock from hemothorax caused by pacemaker perforation, two weeks after insertion. Device interrogation showed normal function. Chest X-ray and echocardiogram missed lead dislocation and the diagnosis was made on computed tomogram (CT) of the chest. Following surgical repair, a new ventricular pacemaker was placed transvenously in the right ventricular septum. This case illustrates that CT scan of the chest should be performed in all patients in whom cardiac perforation by pacemaker is suspected but not diagnosed on chest X-ray and echocardiogram. Normal functioning of pacemaker on device interrogation does not exclude perforation.
منابع مشابه
Subacute Right Ventricular Perforation by Pacemaker Lead Causing Left-Sided Hemothorax and Epicardial Hematoma
We report a case of right ventricular wall perforation by a pacemaker lead in a 78-year-old female 18 days after a permanent pacemaker insertion. This injury necessitated explant of the perforating lead and implantation of a new one with surgical backup. We review the literature and discuss the possible risk and protective factors including lead models that were associated with higher incidence...
متن کاملSurgical Repair of Subacute Right Ventricular Perforation after Pacemaker Implantation
We report an 84-year-old woman who presented with right ventricular perforation 4 days after pacemaker implantation for syncope due to sick sinus syndrome. Median sternotomy revealed no pericardial effusion, but the pacing lead had penetrated the right ventricle and pericardium. When the pleura was opened, the tip of the lead was seen in the visceral pleura. The lead was cut in the pericardial ...
متن کاملExtraction of a dual-chamber pacemaker and inserting of a new automatic implantable cardioverter defibrillator
BACKGROUND The cardiovascular illnesses are in the middle of the foremost reasons of death around the world. Deaths in Europe, from sudden cardiac death (SCD), reach nearby 700,000 individuals every year. In the United States, statistics point to the existence of nearly 1 million yearly deaths from cardiovascular sickness, of which 330,000 are the consequence of abrupt. The significance of auto...
متن کاملSubacute right ventricular pacemaker lead perforation: evaluation by echocardiography and cardiac CT
A 77-year-old female patient with a history of chronic obstructive pulmonary disease and paroxysmal atrial fibrillation presented to our emergency department with collapse and was diagnosed with sick sinus syndrome. Before pacemaker implantation, echocardiography showed normal dimensions of both atria and ventricles and normal systolic left and right ventricle (RV) function. A DDD-R pacemaker w...
متن کاملLife Threatening Perforation of Pacemaker Atrial Lead through the Right Atrium and the Right Lung
We report the case of a 65year old female patient who was urgently admitted to our institution with hemothorax after pacemaker implantation. The bichamber pacemaker had been implanted one week before admission and the active fixation lead caused perforation of the right atrial wall and penetration of the right lung. Transthoracic echocardiography demonstrated a minimal cardiac effusion but ches...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015