2-methylbutyryl-CoA dehydrogenase deficiency in Hmong infants identified by expanded newborn screen.
نویسندگان
چکیده
In April 2000, the Wisconsin Newborn Screening Program implemented tandem mass spectrometry (MS/MS) technology to expand the newborn screening panel from 13 to 48 disorders, the majority of which are inborn errors of metabolism. Among other tests, this technology measures the acylcarnitine profile from blood spots collected from infants at 24 to 48 hours of age. During the first 5.75 years of expanded screening, 27 infants were identified with elevated C5-acylcarnitine concentrations, an unexpectedly high number for any inborn error of metabolism. For these infants, elevated C5-acylcarnitines suggested a diagnosis of isovaleric acidemia (IVA), a metabolic defect of leucine metabolism. Subsequent testing showed that the infants did not have isovaleric acidemia, but did have 2-methylbutyryl-CoA dehydrogenase deficiency or 2-MBAD deficiency, a newly described defect of isoleucine metabolism. (An official abbreviation has not been established for this disorder. Other abbreviations include SBCADD, 2-MBG, and 2-MBCD deficiency.) All but 1 of the 27 infants identified with 2-MBAD deficiency are offspring of Hmong parents. To date, those diagnosed with the disorder in the Hmong community have been largely asymptomatic, though further research is needed to determine whether newborns with 2-MBAD deficiency are at risk for neurodevelopmental disorders.
منابع مشابه
Newborn screening for medium chain acyl-CoA dehydrogenase deficiency: performance improvement by monitoring a new ratio.
Medium chain acyl-CoA dehydrogenase (MCAD) deficiency is a fatty acid oxidation disorder included on newborn screening (NBS) panels in many regions that have expanded to using tandem mass spectrometry for acylcarnitine screening. False positive (FP) screening results for MCAD deficiency have previously been linked to very low birth weight (VLBW) infants and those who are heterozygous for the co...
متن کاملElectrospray tandem mass spectrometry for analysis of acylcarnitines in dried postmortem blood specimens collected at autopsy from infants with unexplained cause of death.
BACKGROUND Deaths from inherited metabolic disorders may remain undiagnosed after postmortem examination and may be classified as sudden infant death syndrome. Tandem mass spectrometry (MS/MS) may reveal disorders of fatty acid oxidation in deaths of previously unknown cause. METHODS We obtained filter-paper blood from 7058 infants from United States and Canadian Medical Examiners. Acylcarnit...
متن کاملThe health system impact of false positive newborn screening results for medium-chain acyl-CoA dehydrogenase deficiency: a cohort study
BACKGROUND There is no consensus in the literature regarding the impact of false positive newborn screening results on early health care utilization patterns. We evaluated the impact of false positive newborn screening results for medium-chain acyl-CoA dehydrogenase deficiency (MCADD) in a cohort of Ontario infants. METHODS The cohort included all children who received newborn screening in On...
متن کامل2-methylbutyryl-CoA dehydrogenase deficiency associated with autism and mental retardation: a case report
BACKGROUND 2-methylbutyryl-CoA dehydrogenase deficiency or short/branched chain acyl-CoA dehydrogenase deficiency (SBCADD) is caused by a defect in the degradation pathway of the amino acid L-isoleucine. METHODS We report a four-year-old mentally retarded Somali boy with autism and a history of seizures, who was found to excrete increased amounts of 2-methylbutyryl glycine in the urine. The S...
متن کاملTandem mass spectrometric analysis for amino, organic, and fatty acid disorders in newborn dried blood spots: a two-year summary from the New England Newborn Screening Program.
BACKGROUND Tandem mass spectrometry (MS/MS) is rapidly being adopted by newborn screening programs to screen dried blood spots for >20 markers of disease in a single assay. Limited information is available for setting the marker cutoffs and for the resulting positive predictive values. METHODS We screened >160 000 newborns by MS/MS. The markers were extracted from blood spots into a methanol ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- WMJ : official publication of the State Medical Society of Wisconsin
دوره 106 1 شماره
صفحات -
تاریخ انتشار 2007