Formaldehyde around 3.5 and 5.7-μm: measurement and calculation of broadening coefficients
نویسندگان
چکیده
Selfand N2-broadening coefficients of H2CO have been retrieved in both the 3.5 and 5.7-μm spectral regions. These coefficients have been measured in FT spectra for transitions with various J (from 0 to 25) and K values (from 0 to 10), showing a clear dependence with both rotational quantum numbers J and K. First, an empirical model is presented to reproduce the rotational dependence of the measured selfand N2-broadening coefficients. Then, calculations of N2-broadening of H2CO were made for some for 3296 2 transitions using the semi-classical Robert-Bonamy formalism. These calculations have been done for various temperatures in order to obtain the temperature dependence of the line widths. Finally, selfand N2-broadening coefficients, as well as temperature dependence of the N2-widths has been generated to complete the whole HITRAN 2008 version of formaldehyde (available as supplementary materials).
منابع مشابه
N2-broadening coefficients of methyl chloride at room temperature
Methyl chloride is of interest for atmospheric applications, since this molecule is directly involved in the catalytic destruction of ozone in the lower stratosphere. In a previous work [Bray et al. JQSRT 2011;112:2446], lines positions and intensities of self-perturbed CH3Cl and CH3Cl have been studied into details for the 3.4 μm spectral region. The present work is focused on measurement and ...
متن کاملRapid communication Detection of formaldehyde using mid-infrared difference-frequency generation
Real-time detection and measurement of subppm levels of formaldehyde in ambient air using diodepumped 3.5 μm difference-frequency generation (DFG) in periodically poled LiNbO3 (PPLN) is reported. Minimum detectable concentration of 30 ppb was achieved with a compact, portable room-temperature gas sensor configured for formaldehyde (H2CO) detection. This sensitivity, coupled with high selectivit...
متن کاملCalculation of airkerma conversion factor to personal dose equivalent at various depths using the Monte Carlo Code GATE
Several studies have been done with the aim of improving the quality of the radiation protection measurement in radiology and nuclear medicine. Among different subjects which are capable to be considered in this area, the measurement of the operational quantities of protection against the radiation ,such as, personal dose equivalent ,HP(d), at different depths (d=0.07mm, 3mm, 10mm) is an impor...
متن کاملX-ray peak broadening analysis in LaMnO3+δ nano-particles with rhombohedral crystal structure
In this work, structural and magnetic properties of LaMnO3+δ compound prepared by citrate precursor method and annealed in presence of oxygen are investigated. The structural characterization of LaMnO3+δ by X-ray powder diffraction and using X’pert package and Fullprof program is evidence for a rhombohedral structure (R-3c space group) confirmed by FTIR measurement. The magnetic measurements sh...
متن کاملFormaldehyde measurement based on its electrocatalytic oxidation by Ni-TiO2 nanoparticles/chitosan modified carbon paste electrode as an effective method
In this work, for the first time, a new and effective bulk modified carbon paste electrode (CPE) was prepared by TiO2 nanoparticles and chitosan and then Ni2+ ions were incorporated to this electrode by immersion of the modified electrode in nickel chloride solution. The values of electron transfer coefficient, charge-transfer rate constant and electrode surface coverage f...
متن کامل