Cranial vault reconstruction using computer-designed polyetheretherketone (PEEK) implant: case report.

نویسندگان

  • Erika Chacón-Moya
  • José Francisco Gallegos-Hernández
  • Sandra Piña-Cabrales
  • Fabricio Cohn-Zurita
  • Alberto Goné-Fernández
چکیده

BACKGROUND Reconstruction of the bones of the skull is a complex procedure and represents a challenge for the surgical team. It is generally performed in patients who have loss of the cranial vault secondary to chronic infection or uncontrolled osteoradionecrosis, indicating a greater chance of failure or rejection of the materials used for repair of the defect. Selection of material to replace the cranial vault is complex due to the diversity of existing products. The ideal material is inert, lightweight, easy to fit and adaptable to the defect, offering the best aesthetic and functional results. Computer design of the implant makes this process easier by providing an implant specific to each individual patient and defect. CLINICAL CASE We report the case of a patient who was diagnosed with esthesioneuroblastoma and was treated with anterior craniofacial resection and radiotherapy. Osteomyelitis and osteoradionecrosis were consequent complications with loss of the cranial vault in the frontal region. The defect was reconstructed with a polyetheretherketone (PEEK) computer-designed implant based on the defect evaluated by computed tomography. Results obtained are shown below. CONCLUSIONS The PEEK computer-designed implant is a safe and easy to use alternative with great adaptability to cranial vault defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Case Report: Destructive Neuroendocrine Cranial Tumour and The Role Of Pre-Fashioned Polyetheretherketone (PEEK) Cranioplasty

Medical implant devices have evolved in the past decade and now many surgical specialties have turned to polyetheretherketone (PEEK) devices for its ideal properties. In Neurosurgery, PEEK has its role in many operations such as cervical cages after anterior cervical discectomy and as a prosthetic implant for cranioplasty where autologous cranioplasty is not possible. We discuss our case of a p...

متن کامل

Abstract: Intraoperative Location of the Greater Occipital Nerve in Patients Undergoing Migraine Surgery

METHODS: A retrospective chart review was performed at a tertiary academic medical center for all patients who underwent microvascular surgery of the scalp from July 2011 through December 2016. Reconstructions were evaluated by type of flap utilized (myofascial, myocutaneous, fasciocutaneous, or osteocutaneous) as well as type of cranial reconstruction performed (titanium implant, polyetherethe...

متن کامل

Correction of a mandibular asymmetry after fibula reconstruction using a custom-made polyetheretherketone (PEEK) onlay after implant supported occlusal rehabilitation.

This study describes an unusual case of mandibular asymmetry after fibula free flap reconstruction in a young man following major facial trauma that was corrected using a custom-made polyetheretherketone prosthesis. There is little information in the literature on the use of alloplasts to correct mandibular asymmetry as interest in 'aesthetic re-modelling' has traditionally focused on nasal, zy...

متن کامل

Osseointegration of nanohydroxyapatite- or nano-calcium silicate-incorporated polyetheretherketone bioactive composites in vivo

Polyetheretherketone (PEEK) exhibits appropriate biomechanical strength as well as good biocompatibility and stable chemical properties but lacks bioactivity and cannot achieve highly efficient osseointegration after implantation. Incorporating bioceramics into the PEEK matrix is a feasible approach for improving its bioactivity. In this study, nanohydroxyapatite (n-HA) and nano-calcium silicat...

متن کامل

Patient-specific polyetheretherketone implants for repair of craniofacial defects.

BACKGROUND Large cranial defects represent reconstructive challenges. Polyetheretherketone (PEEK) implants are preoperatively tailored to the exact size of the defect and exhibit an excellent combination of strength, durability, and environmental resistance. This study presents our experience with patient-specific PEEK implants with computer modeling. METHODS A retrospective chart review was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cirugia y cirujanos

دوره 77 6  شماره 

صفحات  -

تاریخ انتشار 2009