A 10MS/s 11-b 0.19mm2 Algorithmic ADC with Improved Clocking

نویسندگان

  • Min Gyu Kim
  • Pavan Kumar Hanumolu
  • Un-Ku Moon
چکیده

A 10Ms/s 11-b algorithmic ADC with an active area of 0.19mm is presented. Using an improved clocking scheme, this design overcomes the speed limit of algorithmic ADCs. The proposed ADC employs amplifier sharing, DC offset cancellation, and input memory effect suppression to reduce area and power, and achieve high linearity. The ADC implemented in a 0.13μm thick gate-oxide CMOS process achieves 69dB SFDR, 58dB SNR, and 56dB SNDR, while consuming 3.5mA from 3V supply.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A 1V 11fJ/Conversion-Step 10bit 10MS/s Asynchronous SAR ADC in 0.18μm CMOS

This paper presents a 10-bit SAR ADC using a variable window function to reduce the unnecessary switching in DAC network. At 10-MS/s and 1-V supply, the ADC consumes only 98 μW and achieves an SNDR of 60.97 dB, resulting in an FOM of 11 fJ/Conversion-step. The prototype is fabricated in a 0.18μm CMOS technology.

متن کامل

A Reconfigurable 10MS/s to 100MS/s, 0.5V to 1.2V, 0.98mm, 10b Low-Power 0.13um CMOS Pipeline ADC

This work describes a reconfigurable 10MS/s to 100MS/s, 0.5V to 1.2V, 0.98mm, 10b low-power 0.13um CMOS two-step pipeline ADC. The SHA employs gate-bootstrapped sampling switches and a two-stage amplifier based on a low-threshold NMOS differential input stage to obtain 10b accuracy even at a 0.5V supply. A signal-isolated all directionally symmetric layout reduces the MDAC capacitor mismatch wh...

متن کامل

Design of High Speed Sine Wave Flash Adc for Uwb Applications

Multigigahertz flash ADC is limited by sampling clock timing jitter. Since it is used in high frequency applications it is essential to remove jitter effects which will reduce the efficiency of ADC. This paper describes the effect of clock transition time on the spurious free dynamic range of a CMOS sample and hold circuit. To improve SFDR the effect of finite clock transition time of the signa...

متن کامل

A 12-bit 100kS/s SAR ADC for Biomedical Applications

This paper describes a 12-bit 100kS/s successive approximation register analog-todigital converter (SAR ADC) for biomedical system. Both top-plate sampling technique and VCM-based switching technique are applied to the capacitor digital-to-analog converter (CDAC) to implement a 12-bit SAR ADC with 10-b capacitor array DAC. To enhance the linearity of proposed ADC, thermometer decoder is used in...

متن کامل

Assessment of diagnostic value of DWI technique in the evaluation of liver fibrosis

Introduction: The liver fibrosis is caused by extracellular accumulation of cluster, glycos amino glycans and proteoglycans, which this extracellular accumulation may limit the penetration and molecular movement of water in the tissue, so the Diffusion weighted imaging(DWI) technique is due to the sensitivity to the movement and release of water molecules Can show this restrict...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006