Spatially encoded phase-contrast MRI-3D MRI movies of 1D and 2D structures at millisecond resolution.

نویسندگان

  • Klaus-Dietmar Merboldt
  • Martin Uecker
  • Dirk Voit
  • Jens Frahm
چکیده

This work demonstrates that the principles underlying phase-contrast MRI may be used to encode spatial rather than flow information along a perpendicular dimension, if this dimension contains an MRI-visible object at only one spatial location. In particular, the situation applies to 3D mapping of curved 2D structures which requires only two projection images with different spatial phase-encoding gradients. These phase-contrast gradients define the field of view and mean spin-density positions of the object in the perpendicular dimension by respective phase differences. When combined with highly undersampled radial fast low angle shot (FLASH) and image reconstruction by regularized nonlinear inversion, spatial phase-contrast MRI allows for dynamic 3D mapping of 2D structures in real time. First examples include 3D MRI movies of the acting human hand at a temporal resolution of 50 ms. With an even simpler technique, 3D maps of curved 1D structures may be obtained from only three acquisitions of a frequency-encoded MRI signal with two perpendicular phase encodings. Here, 3D MRI movies of a rapidly rotating banana were obtained at 5 ms resolution or 200 frames per second. In conclusion, spatial phase-contrast 3D MRI of 2D or 1D structures is respective two or four orders of magnitude faster than conventional 3D MRI.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intra- and interobserver variability of left ventricular diastolic inflow parameters measured by three chamber view 2D cine three-directionally encoded (3Ch. 2D-cine-3 dir.) Phase contrast MR velocity vector map

Background One-directionally-encoded cine 2D Phase-Contrast MRI (PC MRI) of basal short axial image is generally used for the evaluation of diastolic function, but has potential limitations due to the longitudinal cardiac motion and inflow direction. Time-resolved 3D PC MRI is not affected by the flow direction and left ventricular motion, however, requires long acquisition time. In theory, thr...

متن کامل

Spatially resolved biologic information from in vivo EPRI, OMRI, and MRI.

EPR spectroscopy can give biologically important information, such as tissue redox status, pO2, pH, and microviscosity, based on variation of EPR spectral characteristics (i.e., intensity, linewidth, hyperfine splitting, and spectral shape of free radical probes. EPR imaging (EPRI) can obtain 1D-3D spatial distribution of such spectral components using several combinations of magnetic field gra...

متن کامل

Delayed phases of contrast MRI, can it be valuable in multiple sclerosis active phase diagnosis?

Background: Observing the enhancing plaques in magnetic resonance imaging (MRI) is one of the most valuable diagnostic modalities in confirming the diagnosis of multiple sclerosis (MS), its recurrence and for better detection of active disease. Since active lesions discovery can improve designating diffusion in time diagnosis of MS and controlling disease activity, and there is not any definite...

متن کامل

A qualitative and quantitative assessment of cardiac cine Phase contrast MRI: comparison of image quality between 2D and 3D acquisition

Background 3D and gapless multi-slice 2D cine Phase contrast (PC) MRI enables the visualization and analysis of 4D (3D + time) intracardiac flow. However, the image quality which affects the accuracy of segmentation of left ventricle (LV) has not been discussed. In this study, we compared the magnitude image and the source image of PC MR angiography (MagSUM) derived from both 2D and 3D PC MRI. ...

متن کامل

Six-Fold Acceleration of High-Spatial Resolution 3D SPACE MRI of the Knee Through Incoherent k-Space Undersampling and Iterative Reconstruction-First Experience.

PURPOSE The aim of this study was to prospectively test the hypothesis that 6-fold acceleration of a 3-dimensional (3D) turbo spin echo (TSE) magnetic resonance imaging (MRI) pulse sequence with k-space undersampling and iterative reconstruction is feasible for fast high spatial resolution MRI of the knee, while yielding similar image quality and diagnostic performance when compared with a conv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 66 4  شماره 

صفحات  -

تاریخ انتشار 2011