Experimental evaluation of an implant mounting within a bone tissue at the interface between the implant surface and the bone tissue in cement-amalgam fastening

نویسندگان

  • M. Zaczyk
  • D. Jasińska-Choromańska
چکیده

The aim of the work was to determine quality of an implant mounting within a bone and its strength, as well as to find out, which factors, occurring in the implant-bone system, influence the condition of the contact of an implant mounted within a living tissue the most. The quality of an implant mounting within a bone was experimentally determined by testing 18 samples that had been prepared beforehand.. The experiment consisted in loading the prepared samples with pressures whose character imitated loading of a human limb during a fast gait [3]. Mounting of a fragment of a steel endoprosthesis mandrel within a fragment of the top of the closer thigh bone was realized with the same precision and the same fit in the case of all the tested samples, using a mounting method identical with a technique of mounting an endoprosthesis during its surgical implantation [1,3]. The prepared samples imitated mounting of the endoprosthesis mandrel within the bone tissue. The quality of the fastening was determined by recording values of displacements of the mandrel mounted within the bone tissue for an applied load, i.e. a force occurring within the studied joint during a gait process[1,2,3]. The measurements consisted in recording a displacement of the mandrel mounted within the bone with respect to the bone tissue in direction the load acts. The way the tests were performed is schematically shown in Fig. 1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی هیستولوژیک و هیستومرفومتریک استخوان‌سازی در مجاورت ایمپلنت تیتانیوم با و بدون Bio-oss در فضای مدولاری درشت‌نی خرگوش

Background and Objective: Nowadays, various biomaterials have been presented for regeneration of osseous defects and Bio-oss is one of them. The objective of this study was evaluation of Bio-oss function in intramedullary space of rabbit`s tibia near titanium implant. Materials and Methods: In this study, 12 white New Zealand rabbits were selected and randomly divided into control and experimen...

متن کامل

ارزیابی کارایی ایمپلنت‌های دندانی plus Swiss با استفاده از معیارهای کلینیکی و رادیوگرافیک

  Introduction: Swiss plus dental implant is one of the many different implant systems that have been proposed recently. The aim of this study was to evaluate survival rate of Swiss plus dental implants and surrounding soft and hard tissue based clinical and radiographic parameters.   Materials & Methods: In a post perspective observational descriptive study, 106 patients (47 women and 59 men) ...

متن کامل

Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...

متن کامل

The axisymmetric computational study of a femoral component to analysis the effect of titanium alloy and diameter variation.

This work presents a numerical approach in order to predict the influence of implant material stiffness in a femoral component design when submitted in compression. The implant success depends on the transferred load to the neighboring bone. The finite element method can be used to analysis the stress and strain distribution in the femoral component allowing to improve the implant selection. Fo...

متن کامل

Cement-Implant Interface Fracture Failure by Crack Initiation Due to Interface Cavity Stress Concentration

Nowadays total joint replacements are widely used in the world, so in average 800,000 joint surgeries are done yearly only in Europe and North America. However implant loosening is and remains as the major issue of all implant failures and therefore causes revision surgery procedures. Studies and experiments have identified poor fixation of implants most likely is the main cause of long term im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010