Analog processing of signals from a CZT strip detector with orthogonal coplanar anodes
نویسندگان
چکیده
We present the requirements, design, and performance of an analog circuit for processing the noncollecting anode strip signals from a cadmium zinc telluride (CZT) strip detector with orthogonal coplanar anodes. Detector signal simulations and measurements with a prototype are used to define the range of signal characteristics as a function of location of the gamma interaction in the detector. The signals from the non-collecting anode strip electrodes are used to define two of the three spatial coordinates including the depth of interaction, the z dimension. Analog signal processing options are discussed. A circuit to process the signals from the non-collecting anode strips and extract from them the depth of interaction is described. The circuit employs a time-over-threshold (TOT) measurement. The performance of the detector prototype with a preliminary version of this circuit is presented, and future development work is outlined. Figure 3. CZT, imaging, gamma-ray, electronics
منابع مشابه
Stability and Characteristics of Large CZT Coplanar Electrode Detectors
The single polarity charge sensing method based on coplanar grid electrodes has demonstrated promising results on CZT detectors having volumes of ~1 cm. This paper presents the performance of two coplanar grid CZT detectors having dimensions of 1.5 1 5 1.0 cm2, among the largest CZT spectrometers that have been reported. Energy resolutions of 2.3% and 2.0% full-width half-maximum were obtained ...
متن کاملEstimate of Large CZT Detector Absolute Efficiency
This paper presents a simulation of the spectroscopic performance of two large CZT coplanar detectors, 1.5 1.5 cm area and 1.0 cm thick, with coplanar anodes. A code, based on the GEANT libraries and classical Monte Carlo sampling, was developed to simulate experimental scenarios. This code adapts the GEANT capabilities for simulating complex detection systems for spectroscopic studies. Detecto...
متن کاملStudy of a high-resolution, 3D positioning cadmium zinc telluride detector for PET.
This paper investigates the performance of 1 mm resolution cadmium zinc telluride (CZT) detectors for positron emission tomography (PET) capable of positioning the 3D coordinates of individual 511 keV photon interactions. The detectors comprise 40 mm × 40 mm × 5 mm monolithic CZT crystals that employ a novel cross-strip readout with interspersed steering electrodes to obtain high spatial and en...
متن کاملRF strip-line anodes for Psec large-area MCP-based photodetectors
We have designed and tested economical large-area RF strip-line anodes made by silk-screening silver onto inexpensive plate glass, for use in microchannel plate photodetectors to provide measurements of time, position, integrated charge, and pulse waveform shapes. The 229-mm-long anodes are modular, and can be attached in series for economy in electronics channel-count. Measurements of the anod...
متن کاملSimulation studies of CZT Detectors as Gamma-Ray Calorimeter
Several astrophysics and nuclear physics applications require the detection of photons in the energy range of keV up to several MeV with good position and energy resolution. For certain applications Cadmium Zinc Telluride (CZT) detectors might be the detector option of choice. Up to now, CZT detectors have mainly been used in the energy range between a few keV and ∼1 MeV. They operate at room t...
متن کامل