Adaptive closed-loop control provides blood-glucose regulation using dual subcutaneous insulin and glucagon infusion in diabetic Swine.
نویسندگان
چکیده
BACKGROUND In order to stave off deleterious complications of the disease, the ultimate task for people with diabetes is to maintain their blood glucose in euglycemic range. Despite technological advancements, conventional open-loop therapy often results in prolonged hyperglycemia and episodic hypoglycemia, in addition to necessitating carbohydrate counting, frequent glucose monitoring, and drug administration. The logical conclusion in the evolution of exogenous insulin therapy is to develop an automated closed-loop control system. METHODS Eleven closed-loop control experiments were conducted in four anesthetized diabetic pigs, with carbohydrate loads simulated by intravenous glucose administration through ear-vein catheters. Type 1 diabetes-like pathology was induced using intravenous administration of cytotoxin streptozotocin. The augmented model-predictive control algorithm accounts for the accumulation of subcutaneous insulin, which is critical in avoiding excessive insulin dosing. RESULTS Control results consistently showed successful blood-glucose regulation to euglycemic range within 80-120 minutes after intravenous glucose loads, with no incidence of hypoglycemia. This is consistent with a negative oral glucose tolerance test for diabetes and is the optimal postprandial regulation that can be achieved with subcutaneous insulin administration. Results also demonstrated the potency of subcutaneous glucagon in staving off episodic hypoglycemia and revealed efficacy of the control algorithm in coping with a twofold variation in subject weights, while simultaneously overlooking erratic blood-glucose fluctuations. CONCLUSIONS Using an automated adaptive glucose-control system, we show successful blood-glucose regulation in vivo and establish, definitively, the plausibility and practicality of closed-loop blood-glucose control using subcutaneous insulin and glucagon infusion in type 1 diabetes. The control system strikes an intricate balance between tight blood-glucose control and optimal drug consumption, while simultaneously maintaining emphasis on simplicity and reliability.
منابع مشابه
A feasibility study of bihormonal closed-loop blood glucose control using dual subcutaneous infusion of insulin and glucagon in ambulatory diabetic swine.
BACKGROUND We sought to test the feasibility and efficacy of bihormonal closed-loop blood glucose (BG) control that utilizes subcutaneous (SC) infusion of insulin and glucagon, a model-predictive control algorithm for determining insulin dosing, and a proportional-derivative control algorithm for determining glucagon dosing. METHODS Thirteen closed-loop experiments (approximately 7-27 h in le...
متن کاملPharmacodynamics and stability of subcutaneously infused glucagon in a type 1 diabetic Swine model in vivo.
BACKGROUND The objective of this study was to determine the in vivo pharmacodynamics of glucagon and to test its glycemic effect over days by assessing its time course of activity and potency in a type 1 diabetic swine model. METHODS Individual experiments were conducted in different pigs using glucagon preparations that were reconstituted on different days and stored at room temperature or n...
متن کاملComparing Effects of Continuous Insulin Infusion with or without Subcutaneous Glargine Insulin on Glycemic Control in Diabetic Patients Undergoing Coronary Artery Bypass Graft (CABG)
OBJECTIVE: Hyperglycemia is associated with increased morbidity and mortality in diabetic patients following coronary artery bypass grafting. Tight glycemic control in perioperative period can reduce these events. The goal of this study was to determine whether combination of continuous infusion and subcutaneous glargine as a basal insulin could improve glycemic control. MATERIAL AND METHODS:...
متن کاملRobust Adaptive Neural Control of the Blood Glucose for Type 1 Diabetic Patients in Presence of Meals
In this paper, the blood glucose control for type 1 diabetic patients in the presence of model uncertainties and uncertain meals is considered. In order to present an efficient control approach, it is assumed that the dynamics describe the mechanism of the blood glucose regulation in type 1 diabetic patients are completely unknown. Hence, based on the universal approximation property of the rad...
متن کاملChaotic dynamic analysis and nonlinear control of blood glucose regulation system in type 1 diabetic patients
In this paper, chaotic dynamic and nonlinear control in a glucose-insulin system in types I diabetic patients and a healthy person have been investigated. Chaotic analysis methods of the blood glucose system include Lyapunov exponent and power spectral density based on the time series derived from the clinical data. Wolf's algorithm is used to calculate the Lyapunov exponent, which positive val...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of diabetes science and technology
دوره 1 2 شماره
صفحات -
تاریخ انتشار 2007