Direct and indirect free thyroxine assay methods: theory and practice.
نویسنده
چکیده
BACKGROUND For the diagnosis of thyroid disease, measurement of "free hormone" is generally accepted as an appropriate measure. However, valid assays measuring the free fraction of thyroxine (FT4) ideally must perform without bias, despite large variations in the concentrations and affinities of serum T4-binding proteins in the population. Several approaches have been taken to overcome such bias, and these have created considerable controversy in the field over the past decade. APPROACH This review, from both a historical and an analytical standpoint, charts the progress made over more than 30 years in improvements to the performance of assays in common use for the measurement of FT4 in serum or plasma. It reexamines the theory behind early approaches to such assays [for example, the free thyroxine index (FTI) method], that preceded more accurate, two-step immunoassays or one-step analog techniques. It evaluates the continuous refinements to the latter assays that by now have largely supplanted the FTI approach and where the deficiencies that so exercised clinical chemists in the past have been virtually eliminated in the leading assays. CONTENT The basic Mass Action theory underpinning all such methods is discussed by assessing how far each particular approach obeys the criteria the theory imposes. In this, it is not the intention of the review to dissect individual commercial or academic assays, but rather to give guidance where appropriate as to how any assay said to measure FT4 can be conveniently evaluated by those intending to use it. Examples are given where inappropriate tests may wrongly imply assay invalidity by misinterpreting how FT4 assays work. SUMMARY Detailed knowledge of the underlying theory is essential when devising tests for direct FT4 assays, to ensure that such tests do not overstep the practical limits of assay validity.
منابع مشابه
Concentration of thyroxine-binding globulin: value of direct assay.
The concentration of thyroxine-binding globulin (TBG) in the serum can now be measured by direct assays that are simple and inexpensive. Comparison of a direct measurement of TBG concentration with a widely used indirect method (Thyopac-3) showed that the indirect method was inaccurate when TBG concentrations were high. This will result in an increase in the derived free thyroxine index (FTI), ...
متن کاملTHEORY, EXPERIMENT AND PRACTICE OF SLAG ATTACK OF REFRACTORIES
Penetration and dissolution mechanisms are reviewed for predominantly single-phase oxide, two phase oxide and oxide-carbon composite refractories by liquid silicate slags. Theoretical models of these processes, as well as static (sessile drop, dipping and crucible) and dynamic (rotating finger and rotary slag) experimental tests, along with their practical limitations are considered. Direct (co...
متن کاملEvaluation of new kits for the assessment in vitro of thyroid function by determination of serum total thyroxine, free TBG capacity, and free thyroxine index using Sephadex G-25 and '25I-labelled triiodothyronine and thyroxine
SYNOPSIS A trial was carried out on 134 patients of new kits (Ames Co) using columns of Sephadex G-25 for the determination of serum total thyroxine (Tetralute test) and for the indirect estimation of serum free thyroxine-binding globulin capacity (Trilute test). Both new methods were quicker and easier than the reference resin methods and of similar precision. The two measurements when combine...
متن کاملtotal thyroxine, free TBG capacity, and free thyroxine index using Sephadex G-25 and '25I-labelled triiodothyronine and thyroxine
SYNOPSIS A trial was carried out on 134 patients of new kits (Ames Co) using columns of Sephadex G-25 for the determination of serum total thyroxine (Tetralute test) and for the indirect estimation of serum free thyroxine-binding globulin capacity (Trilute test). Both new methods were quicker and easier than the reference resin methods and of similar precision. The two measurements when combine...
متن کاملHigh mobility group protein 1 (HMGB1) quantified by ELISA with a monoclonal antibody that does not cross-react with HMGB2.
Thyroid 2000;10:31–9. 6. Sapin R. Serum thyroxine binding capacity-dependent bias in five free thyroxine immunoassays: assessment with serum dilution experiments and impact on diagnostic performance. Clin Biochem 2001;34:367–71. 7. Christofides ND. Free analyte immunoassay. In Wild D, ed. The immunoassay handbook, 2nd ed. London: Nature Publishing Group, 2001:61–77. 8. Christofides ND, Wilkinso...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 47 8 شماره
صفحات -
تاریخ انتشار 2001