Development of Tetrapolar Conductivity Cell for Liquid Measurement Application
نویسندگان
چکیده
This paper deals with the development of a liquid measuring instrumentation using the popular tetrapolar electrode configuration. The system consists of four-electrode ring shape using Cromium metal plate and a small measurement. The developed instrument is calibrated with the help of prepared saline solution prepared in lab. A liquid of known parameter is placed inside the measurement cell and current is injected through excitation electrode with certain frequency and voltage drop is measured across electrode potential terminals. From this voltages and cell constant value, the conductivity, resistivity and impedance of the measured liquid could be determined with acceptable accuracy with more than 96 % compared to the standard measurement. Copyright © 2014 IFSA Publishing, S. L.
منابع مشابه
An Insight into Colloidal Gas Aphron Drainage Using Electrical Conductivity Measurement
In the present paper Electrical Conductivity (EC) of Colloidal Gas Aphron (CGA) suspensions was measured for anionic and cationic surfactants (Sodium Dodecyl Sulfate (SDS) and Tetradecyl Trimethyl Ammonium Bromide (TTAB)). Experiments were made for different concentrations of SDS (6, 8.1, 10 mM) and TTAB (2, 3.51, 5 mM). CGA drainage behavior was observed and measured using 1 liter measuri...
متن کاملDevelopment of a Disposable Electrochemical Sensor based on Nanocomposite/Ionic Liquid Assisted Hollow Fiber-Graphite Electrode for Measurement of Lorazepam Using Central Composite Design
In this study a new method of preconcentration, separation and efficient measuring of so-called hollow fiber solid / liquid phase microextraction has been introduced for the determination of trace amounts of lorazepam (LRZ) in water samples, urine and hair using differential pulse voltammetry. To this end, a hybrid adsorbent material was used that involved ionic liquid assisted magnetic multi-w...
متن کاملTetrapolar measurement of electrical conductivity and thickness of articular cartilage.
A tetrapolar method to measure electrical conductivity of cartilage and bone, and to estimate the thickness of articular cartilage attached to bone, was developed. We determined the electrical conductivity of humeral head bovine articular cartilage and subchondral bone from a 1- to 2-year-old steer to be 1.14+/-0.11 S/m (mean+/-sd, n =11) and 0.306+/-0.034 S/m, (mean+/-sd, n =3), respectively. ...
متن کاملDetermination of Thermo-physical Properties of Non-Newtonian Fluids Using a Coaxial Cylindrical Cell
In this study the thermal conductivity and the volumetric heat capacity of non-Newtonian fluids are investigated. These fluids find many applications in chemical, medical and food industries. They mostly have viscoelastic behavior and generally differ from Newtonian fluids. Two non-Newtonian fluids, solutions of xanthan and carboxy methyl cellulose in water with various concentrations have bee...
متن کاملDecrease of Electrical Conductivity Activation Energy of Co-coated AISI 430 Alloy for the Application of SOFCs
The application of conductive coatings on ferritic stainless steel can decrease electrical conductivity. Theaim of this research was to investigate the electrical conductivity of cobalt coated AISI 430 ferritic stainlesssteel by pack cementation technique. Coated coupons were analyzed using scanning electron microscopy(SEM). Electrical conductivity of the coated substrates was measured as a fun...
متن کامل