Degeneracy, frequency response and filtering in IMRT optimization.

نویسندگان

  • Jorge Llacer
  • Nzhde Agazaryan
  • Timothy D Solberg
  • Claus Promberger
چکیده

This paper attempts to provide an answer to some questions that remain either poorly understood, or not well documented in the literature, on basic issues related to intensity modulated radiation therapy (IMRT). The questions examined are: the relationship between degeneracy and frequency response of optimizations, effects of initial beamlet fluence assignment and stopping point, what does filtering of an optimized beamlet map actually do and how could image analysis help to obtain better optimizations? Two target functions are studied, a quadratic cost function and the log likelihood function of the dynamically penalized likelihood (DPL) algorithm. The algorithms used are the conjugate gradient, the stochastic adaptive simulated annealing and the DPL. One simple phantom is used to show the development of the analysis tools used and two clinical cases of medium and large dose matrix size (a meningioma and a prostate) are studied in detail. The conclusions reached are that the high number of iterations that is needed to avoid degeneracy is not warranted in clinical practice, as the quality of the optimizations, as judged by the DVHs and dose distributions obtained, does not improve significantly after a certain point. It is also shown that the optimum initial beamlet fluence assignment for analytical iterative algorithms is a uniform distribution, but such an assignment does not help a stochastic method of optimization. Stopping points for the studied algorithms are discussed and the deterioration of DVH characteristics with filtering is shown to be partially recoverable by the use of space-variant filtering techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Particle Filtering Based on Biogeography-based Optimization for UGV Navigation

The main challenge with particle filtering is particle degeneracy and the accurate estimation cannot be achieved generally because of serious impoverishment problem, although resampling operation could solve degeneracy to a certain extent. In this paper, we propose an improved particle filtering approach based on biogeography-based optimization (BBO) algorithm, called BBO-PF, for state estimati...

متن کامل

Frequency Control of an Islanded Microgrid based on Intelligent Control of Demand Response using Fuzzy Logic and Particle Swarm Optimization (PSO) Algorithm

Due to the increasing penetration of renewable energies in the power system, the frequency control problem has attracted more attention, while the traditional control methods are not capable of regulating the frequency and securing the stability of the system. In smart grids, demand response as the frequency control tool reduces the dependence on spinning reserve and high cost controllers. In a...

متن کامل

Empirical Mode Decomposition based Adaptive Filtering for Orthogonal Frequency Division Multiplexing Channel Estimation

This paper presents an empirical mode decomposition (EMD) based adaptive filter (AF) for channel estimation in OFDM system.  In this method, length of channel impulse response (CIR) is first approximated using Akaike information criterion (AIC). Then, CIR is estimated using adaptive filter with EMD decomposed IMF of the received OFDM symbol. The correlation and kurtosis measures are used to sel...

متن کامل

INVERSE FREQUENCY RESPONSE ANALYSIS FOR PIPELINES LEAK DETECTION USING THE PARTICLE SWARM OPTIMIZATION

Inverse Transient Analysis (ITA) is a powerful approach for leak detection of pipelines. When the pipe transient flow is analyzed in frequency domain the ITA is called Inverse Frequency Response Analysis (IFRA). To implement an IFRA for leak detection, a transient state is initiated in the pipe by fast closure of the downstream end valve. Then, the pressure time history at the valve location is...

متن کامل

FLUENCE MAP OPTIMIZATION IN INTENSITY MODULATED RADIATION THERAPY FOR FUZZY TARGET DOSE

Although many methods exist for intensity modulated radiotherapy (IMRT) fluence map optimization for crisp data, based on clinical practice, some of the involved parameters are fuzzy. In this paper, the best fluence maps for an IMRT procedure were identifed as a solution of an optimization problem with a quadratic objective function, where the prescribed target dose vector was fuzzy. First, a d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 49 13  شماره 

صفحات  -

تاریخ انتشار 2004