Sensitivity of whole wood stable carbon and oxygen isotope values to milling procedures.
نویسندگان
چکیده
RATIONALE Milling of wood samples is a widely applied preparation method for pooling tree-rings from different trees or periods of several years for determination of δ(13)C and δ(18)O values. In this study, whole wood samples were milled using different procedures in order to evaluate potential effects of this preparation method on δ(13)C and δ(18)O values. METHODS Subsamples of a 5 cm(3) wood piece of a single tree-ring from a lowland white fir were used. The samples were milled with different setups: (i) two and three stainless-steel balls, (ii) 3, 5 and 8 min milling time, and (iii) discontinuous and continuous milling. The δ(13)C values were measured using an elemental analyser connected to an IsoPrime mass spectrometer and δ(18)O values using a Thermo Scientific MAT 253 mass spectrometer and a TC/EA connected by a ConFlo IV. RESULTS The results show that varying the milling procedure does not alter the δ(13)C and δ(18)O values in comparison to non-milled blank samples. For shorter milling times, an increased variance of δ(18)O values is recorded, probably caused by isotopic gradient between early- and latewood portions of the tree-ring and thereby biasing the insufficiently homogenised samples. No overheating effects on the δ(13)C and δ(18)O values were detected. CONCLUSIONS Milling of wood samples for carbon and oxygen isotope analyses is an appropriate preparation method.
منابع مشابه
Contamination risk of stable isotope samples during milling.
RATIONALE Isotope analysis of wood is an important tool in dendrochronology and ecophysiology. Prior to mass spectrometry analysis, wood must be homogenized, and a convenient method involves a ball mill capable of milling samples directly in sample tubes. However, sample-tube plastic can contaminate wood during milling, which could lead to biological misinterpretations. METHODS We tested poss...
متن کاملCorrelation of carbon isotope ratios in the cellulose and wood extractives of Douglas-fir
Cellulose is usually isolated from the other components of plant material for analysis of carbon stable isotope ratios (dC). However, many studies have shown a strong correlation between whole-wood and cellulose dC values, prompting debate about the necessity of cellulose extraction for tree-ring studies. The dC values were measured in whole wood, extractive-free wood, purified cellulose, aceto...
متن کاملروند تغییرات ژئوشیمیایی در سنگ های کربناته نزدیک به کانسار قلع
Geochemical variations of the Pro terozoic dolomite samples close to the ore deposits in the Renison mine area, Tasmania, Austra lia. arc the result of alteration. The oxygen tsotope va lues of the most altered dolomites surrounding the orc deposit indicates that these arc affected oy hot (up to abou t 350°C) hydro thermal nuids. There is a trend of decreasing lighter oxygen and carbon is...
متن کاملAnnual cyclicity in high-resolution stable carbon and oxygen isotope ratios in the wood of the mangrove tree Rhizophora mucronata
In the present study, the high-resolution stable carbon ( 13 C/ 12 C) and oxygen ( 18 O/ 16 O) isotope ratio profiles in the wood of the mangrove Rhizophora mucronata Lam., a tropical tree species lacking distinct growth rings, were investigated. Variations of both isotope ratios revealed a remarkable annual cyclicity with lowest values occurring at the latewood/earlywood boundary (April–May) a...
متن کاملComparison of cellulose extraction methods for analysis of stable-isotope ratios of carbon and oxygen in plant material.
The Jayme-Wise and diglyme-HCl methods for extracting cellulose from plant material for stable-isotope analysis differ considerably in ease of use, with the latter requiring significantly less time and specialized equipment. However, the diglyme-HCl method leaves a small lignin residue in the crude cellulose that may affect stable-isotope values, whereas alpha-cellulose produced by the Jayme-Wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Rapid communications in mass spectrometry : RCM
دوره 28 12 شماره
صفحات -
تاریخ انتشار 2014