Pulmonary toxicity of well-dispersed titanium dioxide nanoparticles following intratracheal instillation
نویسندگان
چکیده
In order to investigate the pulmonary toxicity of titanium dioxide (TiO2) nanoparticles, we performed an intratracheal instillation study with rats of well-dispersed TiO2 nanoparticles and examined the pulmonary inflammation and histopathological changes in the lung. Wistar Hannover rats were intratracheally administered 0.2 mg (0.66 mg/kg) and 1.0 mg (3.3 mg/kg) of well-dispersed TiO2 nanoparticles (P90; diameter of agglomerates: 25 nm), then the pulmonary inflammation responses were examined from 3 days to 6 months after the instillation, and the pathological features were examined up to 24 months. Transient inflammation and the upregulation of chemokines in the broncho-alveolar lavage fluid were observed for 1 month. No respiratory tumors or severe fibrosis were observed during the recovery time. These data suggest that transient inflammation induced by TiO2 may not lead to chronic, irreversible legions in the lung, and that TiO2 nanoparticles may not have a high potential for lung disorder.
منابع مشابه
Pulmonary toxicity of well-dispersed cerium oxide nanoparticles following intratracheal instillation and inhalation
We performed inhalation and intratracheal instillation studies of cerium dioxide (CeO2) nanoparticles in order to investigate their pulmonary toxicity, and observed pulmonary inflammation not only in the acute and but also in the chronic phases. In the intratracheal instillation study, F344 rats were exposed to 0.2 mg or 1 mg of CeO2 nanoparticles. Cell analysis and chemokines in bronchoalveola...
متن کاملEvaluation of Pulmonary Toxicity of Zinc Oxide Nanoparticles Following Inhalation and Intratracheal Instillation
We conducted inhalation and intratracheal instillation studies of zinc oxide (ZnO) nanoparticles in order to examine their pulmonary toxicity. F344 rats were received intratracheal instillation at 0.2 or 1 mg of ZnO nanoparticles with a primary diameter of 35 nm that were well-dispersed in distilled water. Cell analysis and chemokines in bronchoalveolar lavage fluid (BALF) were analyzed at thre...
متن کاملUsefulness of Intratracheal Instillation Studies for Estimating Nanoparticle-Induced Pulmonary Toxicity
Inhalation studies are the gold standard for the estimation of the harmful effects of respirable chemical substances, while there is limited evidence of the harmful effects of chemical substances by intratracheal instillation. We reviewed the effectiveness of intratracheal instillation studies for estimating the hazards of nanoparticles, mainly using papers in which both inhalation and intratra...
متن کاملSystemic Immune Effects of Titanium Dioxide Nanoparticles after Repeated Intratracheal Instillation in Rat
The potential immune effects of titanium dioxide nanoparticles (nano-TiO₂) are raising concern. Our previous study verified that nano-TiO₂ induce local immune response in lung tissue followed by intratracheal instillation administration. In this study, we aim to evaluate the systemic immune effects of nano-TiO₂. Sprague Dawley rats were treated by intratracheal instillation with nano-TiO₂ at do...
متن کاملBasic study of intratracheal instillation study of nanomaterials for the estimation of the hazards of nanomaterials
In order to examine the usefulness of intratracheal instillation of nanoparticles for the screening of the harmful effects of nanoparticles, we performed intratracheal instillation studies of nanomaterials on rats using different delivery devices and postures as a basic study. Multiwall carbon nanotubes (MWCNTs) with a geometric mean length and secondary diameter of 2.16 μm and 752 nm, respecti...
متن کامل