Influence of surface modification on the adhesion between Nitinol wire and fluoropolymer films.

نویسندگان

  • Hyounil Yoon
  • Martin W King
  • Stephen Michielsen
  • Ahmed El-Shafei
  • Eric Johnson
چکیده

PURPOSE One of the current challenges for the medical device industry is how to manufacture and assemble biomedical implants consisting of a metallic wire component and a fluorocarbon film without the use of an adhesive. In an attempt to answer this question, samples of Nitinol wire and fluorinated ethylene-propylene (FEP) film were surface modified by various treatments before being thermally bonded into a composite pull-out strength test specimen and mechanically tested to determine their adhesion strength. METHODS The two surface treatments for Nitinol wire included mechanical roughening with sandpaper, and adding a fluorocarbon coating followed by polymerization and curing by a helium plasma treatment. The two surface treatments for FEP film included helium plasma and helium-oxygen plasma under atmospheric conditions. Scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and contact angle measurements were also taken to characterize the appearance and chemistry of the surfaces before and after modification. A unique pull-out strength test method was developed to assess the level of adhesion between these various candidates. RESULTS The pull-out force for untreated Nitinol bonded to untreated FEP film was 30.5 +/- 2.4 N. Significant improvements of up to 14% in this level of adhesion were obtained with the mechanically roughened Nitinol wire bonded to the helium plasma treated films. However, coating the wire with a liquid fluorocarbon monomer mixture (TG-10) was not successful and after thermal bonding to FEP film the level of adhesion decreased by over 80%. CONCLUSIONS Thus, the bonding strength between the wire and the film can be significantly improved by mechanically roughening the Nitinol wire and treating the FEP film with helium plasma prior to thermal bonding.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlling thin liquid film viscosity via modification of substrate surface chemistry

The viscosity of thin films of liquid poly(dimethylsiloxane) have been studied on silicon and fluoropolymer-coated silicon by means of a perturbation technique applied using colloid probe atomic force microscopy. The liquid film supported by a silicon substrate exhibited a greater viscosity than the bulk liquid, due to the strong interaction between the molecules near to the liquid/solid interf...

متن کامل

Investigation of surface endothelialization on biomedical nitinol (NiTi) alloy: Effects of surface micropatterning combined with plasma nanocoatings.

Plasma nanocoated films with trimethylsilane-oxygen monomers showed outstanding biocompatibility in our previous studies. In this study, endothelialization on biomedical nitinol alloy surfaces was systematically investigated. Our study focuses on elucidating the effects of surface micropatternings with micropores and microgrooves combined with plasma nanocoating. Plasma nanocoatings with contro...

متن کامل

The Study of Collagen Immobilization on a Novel Nanocomposite to Enhance Cell Adhesion and Growth

Background: Surface properties of a biomaterial could be critical in determining biomaterial’s biocompatibility due to the fact that the first interactions between the biological environment and artificial materials are most likely occurred at material’s surface. In this study, the surface properties of a new nanocomposite (NC) polymeric material were modified by combining plasma treatment and...

متن کامل

Fabrication of Spiral Stent with Superelastic/ Shape Memory Nitinol Alloy for Femoral Vessel

Stent is a metal mesh tube for opening the obstructed vessels of the body. Ni-Ti alloy is a suitable metal for fabrication of stent due to its potential for applying the appropriate stress and strain to the vessel walls. In this study, super-elastic Nitinol wire was used to build stent samples usable to open femoral vessel. Ageing was performed at 500°C for different periods of time to determin...

متن کامل

Effects of Surface Modification on the Recovery Time and Stability of Nanostructured Tin Oxide Thick Films Gas Sensors

Along with high sensitivity in detecting gas, the response and recovery times of semiconductor gas sensors are of considerable importance for real life applications. In most cases, the recovery time is more than the response time. At the same time, water vapor present in the ambient, is chemisorbed on the tin oxide, SnO2 surface and the water molecules dissociate into hydroxyl species, which ac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied biomaterials & biomechanics : JABB

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 2010