An integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve.

نویسندگان

  • Mark C S Shu
  • Jeffery M Gross
  • Keith K O'Rourke
  • Ajit P Yoganathan
چکیده

BACKGROUND AND AIM OF THE STUDY An integrated macro/micro approach was used to evaluate flow within the pivots of the Medtronic ADVANTAGE bileaflet heart valve. Results were compared with those obtained with the St. Jude Medical bileaflet heart valve. METHODS The integrated macro/micro approach consists of both a macroscopic hydrodynamic performance assessment and a three-part microscopic flow analysis. The hydrodynamic performance assesses the basic dynamic functions of the valves, while the microscopic flow analysis uses pivot flow visualization, computational fluid dynamics and laser Doppler velocimetry to determine pivot flow characteristics. Pivot flow visualization captures two-dimensional images of the pivot flow, defines the computational fluid dynamics boundary conditions, and validates the computational result. Three-dimensional unsteady computational fluid dynamics simulation reconstructs pivot flow structures. Laser Doppler velocimetry maps pivot velocity field and provides velocity validation for the computational simulation. RESULTS The macroscopic hydrodynamic performance assessment showed the ADVANTAGE and St. Jude Medical valves to be comparable under identical flow conditions. The three techniques in the microscopic analysis mutually confirmed that the pivot design of the ADVANTAGE valve permits continuous-flow washing in the pivot recess, the pivots of both valves are completely wiped twice in a cardiac cycle, and no persistent pivot flow stases are observed. CONCLUSION The integrated macro/micro approach represents a powerful systematic method for determining detailed microscopic flow structures inside the pivots of bileaflet mechanical valves. The use of this technique during the design process of a bileaflet valve can eliminate the persistent flow stases that lead to thrombus formation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Turbulent stress measurements downstream of three bileaflet heart valve designs in pigs.

OBJECTIVE Mechanical heart valves can cause thromboembolic complications, possibly due to abnormal flow patterns that produce turbulence downstream of the valve. The objective of this study was to investigate whether three different bileaflet valve designs would exhibit clinically relevant differences in downstream turbulent stresses. METHODS Three bileaflet mechanical heart valves (Medtronic...

متن کامل

Elliptic st. jude bileaflet mechanical heart valves

St. Jude Medical (SJM) bileaflet mechanical valves were approved by the Food and Drug Administration in 1977. The SJM valve design consists of two semicircular leaflets which pivot on hinges. Compared to other mechanical heart valve prostheses such as ball and cage and tilting disk prosthetic valves, it provides good central flow, the leaflets open completely, and the pressure drop across the v...

متن کامل

Integrated strategy for in vitro characterization of a bileaflet mechanical aortic valve

BACKGROUND Haemodynamic performance of heart valve prosthesis can be defined as its ability to fully open and completely close during the cardiac cycle, neither overloading heart work nor damaging blood particles when passing through the valve. In this perspective, global and local flow parameters, valve dynamics and blood damage safety of the prosthesis, as well as their mutual interactions, h...

متن کامل

Experimental investigation of flow through a bileaflet mechanical heart valve

Turbulent flow downstream of a bileaflet mechanical heart valve is investigated using digital particle image velocimetry. Evolution of flow structures during the systole and diastole phases of a typical cardiac cycle is characterized by obtaining global flow velocity measurements in multiple cross-sections of the flow field. Instantaneous and time-averaged patterns of flow velocity, vorticity, ...

متن کامل

Effects of Bileaflet Mechanical Mitral Valve Rotational Orientation on Left Ventricular Flow Conditions

We studied left ventricular flow patterns for a range of rotational orientations of a bileaflet mechanical heart valve (MHV) implanted in the mitral position of an elastic model of a beating left ventricle (LV). The valve was rotated through 3 angular positions (0, 45, and 90 degrees) about the LV long axis. Ultrasound scans of the elastic LV were obtained in four apical 2-dimensional (2D) imag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of heart valve disease

دوره 12 4  شماره 

صفحات  -

تاریخ انتشار 2003