Analytical goal-setting for monitoring patients when two analytical methods are used.
نویسندگان
چکیده
Serial results from an individual are often obtained using more than one method. Results should be transferable over time and locale. Every method has inherent analytical error, and goals are required to delineate the maximum allowable random (imprecision) and systematic (inaccuracy, bias) errors to facilitate optimal patient care. Based on Harris's proposal [Am J Clin Pathol 1979;72:374-82] that desirable imprecision should be less than or equal to one-half the within-subject biological variation, if the methods have negligible imprecision, then the maximum allowable bias between two methods used for monitoring is one-third of the within-subject biological variation. A more general model has been developed that relates the analytical imprecisions of two methods, and the bias between them, to biological variation. Applying the general formula derived in specific clinical monitoring situations in which a known change in serial results (occurring at a stated probability) stimulates clinical action allows goals for the imprecisions of the two methods and allows the difference in bias between them to be determined quantitatively.
منابع مشابه
Desirable standards of performance for therapeutic drug monitoring.
Therapeutic drug monitoring is an important aspect of clinical chemistry for which no objective analytical goals yet exist. Based on fundamental pharmacokinetic theory, and the current consensus strategy for analytical goal-setting for precision based upon biological variation, a theoretical model allows derivation of the goal that: analytical CV less than or equal to 1/4 [(2T/t - 1)/(2T/t + 1)...
متن کاملSTUDY ON THE FUNDAMENTAL FREQUENCIES OF RECTANGULAR CONCRETE TANKS USING FEM AND ANALYTICAL CODES
Impulsive and convective frequencies are one of the most important subjects for evaluation of the seismic behavior of tanks. These two frequencies are defined by Housner and used for obtaining Rayleigh damping in time history analysis. ACI 350 and NZSEE standards have suggested some analytical solutions for finding convective and impulsive frequencies. These frequencies can also extract from mo...
متن کاملAnalytical goals for determinations of theophylline concentration in serum.
Statistical principles for analytical goal-setting were applied to two medical applications of drug-monitoring data: (a) individualizing dosage requirements by reference to a population-based therapeutic range or to a patient-specific decision value determined by Bayesian decision analysis, and (b) prospective dosing by using pharmaco-kinetic principles. For application a, the analytical goal f...
متن کاملA comparison between numerical and analytical modeling of ECAP
Recent developments in nanostructured products draw considerable attention to ultrafine grained materials. These materials are normally manufactured by different severe plastic deformation (SPD) methods. In the present study, analytical models and finite element method (FEM) are used to calculate strain imposed to a specimen that was deformed by equal channel angular pressing (ECAP). In additio...
متن کاملA routine method for the quantification of the novel antimycotic drug posaconazole in plasma using liquid chromatography-tandem mass spectrometry.
BACKGROUND Posaconazole is now widely used for prophylaxis of invasive fungal infections in immunocompromised patients. The pharmacokinetic properties of the drug argue for therapeutic monitoring, but so far described analytical methods have shortcomings with respect to application in a routine setting. The aim of our work was to develop an analytical method suitable for routine use. METHODS ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 38 11 شماره
صفحات -
تاریخ انتشار 1992