Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes.
نویسندگان
چکیده
PURPOSE To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor. METHODS Twenty-eight adult subjects (32 pseudophakic eyes) having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR) and intraclass correlation coefficient (ICC) were calculated. RESULTS Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951. CONCLUSIONS The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye.
منابع مشابه
Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation
PURPOSE To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. METHODS Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refract...
متن کاملClinical experience with the Tracey technology wavefront device.
PURPOSE In refractive surgery, measuring the total ocular profile of refraction gives more vital information than measuring the cornea alone. We report the first clinical experiments with spatially resolved refractometry using ray tracking principles. Tracey technology was developed in Ukraine by the Institute of Biomedical Engineering in cooperation with the Vardinoyannion Eye Institute of Cre...
متن کاملApparent accommodation and corneal wavefront aberration in pseudophakic eyes.
PURPOSE To assess the relationship between apparent accommodation in pseudophakic eyes, multifocal corneal effects, and wavefront aberrations of the cornea. METHODS In 102 eyes of 86 patients who had undergone phacoemulsification and posterior chamber intraocular lens implantation, the amount of apparent accommodation was measured with an accommodometer. The degree of corneal multifocality wa...
متن کاملUltrasonic biometry of myopic eyes in premature children
Background. The aim of our work was to determine changes in opticalanatomical elements of myopic eyes of full-term and premature children during accommodation by means of precise ultrasonic biometry. Materials and methods. The study was made on healthy full-term children’s eyes with emmetropic refraction (group, n = 20); full-term 1st degree myopic children’s eyes with refraction from -1.0 D to...
متن کاملRefractive change following pseudophakic vitrectomy: a retrospective review
Background: To assess the occurrence and magnitude of refractive change in pseudophakic eyes undergoing pars plana vitrectomy without scleral buckling and to investigate possible aetiological factors. Methods: Retrospective case note review of pseudophakic eyes undergoing pars plana vitrectomy for a variety of vitreo-retinal conditions over a three-year period. Anterior chamber depth was measur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- PloS one
دوره 11 3 شماره
صفحات -
تاریخ انتشار 2016