Titanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study

نویسندگان

  • Langqing Zeng
  • Haifeng Wei
  • Yanjie Liu
  • Wen Zhang
  • Yao Pan
  • Wei Zhang
  • Changqing Zhang
  • Bingfang Zeng
  • Yunfeng Chen
چکیده

BACKGROUND The biomechanical characteristics of midshaft clavicular fractures treated with titanium elastic nail (TEN) is unclear. This study aimed to present a biomechanical finite element analysis of biomechanical characteristics involved in TEN fixation and reconstruction plate fixation for midshaft clavicular fractures. METHODS Finite element models of the intact clavicle and of midshaft clavicular fractures fixed with TEN and with a reconstruction plate were built. The distal clavicle displacement, peak stress, and stress distribution on the 3 finite element models were calculated under the axial compression and cantilever bending. RESULTS In both loading configurations, TEN generated the highest displacement of the distal clavicle, followed by the intact clavicle and the reconstruction plate. TEN showed higher peak bone and implant stresses, and is more likely to fail in both loading configurations compared with the reconstruction plate. TEN led to a stress distribution similar to that of the intact clavicle in both loading configurations, whereas the stress distribution with the reconstruction plate was nonphysiological in cantilever bending. CONCLUSIONS TEN is generally preferable for treating simple displaced fractures of the midshaft clavicle, because it showed a stress distribution similar to the intact clavicle. However, TEN provides less stability, and excessive exercise of and weight bearing on the ipsilateral shoulder should be avoided in the early postoperative period. Fixation with a reconstruction plate was more stable but showed obvious stress shielding. Therefore, for patients with a demand for early return to activity, reconstruction plate fixation may be preferred.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Midshaft Clavicular Fractures With Elastic Titanium Nails

BACKGROUND One of the modern techniques for the treatment of clavicle fracture (Fx) is elastic titanium intramedullary nailing. But, there are different opinions about this technique. We studied this technique in 12 patients with clavicle Fx and assessed its outcome. OBJECTIVES We aimed to study the prognosis of midshaft clavicular Fx treated via minimally invasive stable elastic intramedulla...

متن کامل

Rationale and design of the plate or pin (pop) study for dislocated midshaft clavicular fractures: study protocol for a randomised controlled trial

BACKGROUND To describe the rationale and design of a future study comparing results of plate fixation and Elastic Stable Intramedullary Nailing (ESIN) with a Titanium Elastic Nail (TEN) for adults with a dislocated midshaft clavicular fracture. METHODS/DESIGN Prospective randomized multicenter clinical trial in two level 1 and one level 2 trauma centers. 120 patients between 18 and 65 years o...

متن کامل

Single, superiorly placed reconstruction plate compared with flexible intramedullary nailing for midshaft clavicular fractures: a prospective, randomized controlled trial.

BACKGROUND Previous studies have shown good clinical results in patients with midshaft clavicular fractures treated with reconstruction plate fixation or elastic stable intramedullary nailing. The objective of this study was to compare these methods in terms of clinical and radiographic results. METHODS In this prospective, randomized controlled trial, fifty-nine patients with displaced midsh...

متن کامل

Significant pain reduction and improved functional outcome after surgery for displaced midshaft clavicular fractures

PURPOSE Displaced midshaft clavicular fractures can be treated conservatively as well as operatively by titan elastic nail (TEN) or plate fixation. This survey was performed to evaluate the clinical results of each treatment method and elaborate advantages or possible complications of each modality. METHODS Between 2008 and 2013, 102 patients were prospectively included in our study-37 patien...

متن کامل

Biomechanical comparison of semi-rigid pediatric locking nail versus titanium elastic nails in a femur fracture model

BACKGROUND The treatment for length-unstable diaphyseal femur fractures among school-age children is commonly intramedullary elastic nails, with or without end caps. Another possible treatment is the semi-rigid pediatric locking nail (PLN). The purpose of this biomechanical study was to assess the stability of a length-unstable oblique midshaft fracture in a synthetic femur model stabilized wit...