Differences in sensation level between the Widex Soundtracker and two real-ear analyzers.
نویسندگان
چکیده
BACKGROUND SoundTracker is an algorithm in Widex's Compass fitting software that could potentially be used to estimate a patient's aided sensation level (SL). SoundTracker's accuracy of estimating a patient's SL has never been verified in comparison to SL measured with commercially available real-ear analyzers. PURPOSE Determine whether statistically significant differences are present between the estimated SL of the Widex SoundTracker software application and the measured SL of the Audioscan Verifit and Frye 6500 real-ear analyzers at 500, 1000, 2000, and 4000 Hz. RESEARCH DESIGN This study used a randomized repeated measures design to determine differences in SL between SoundTracker and the Verifit and 6500. STUDY SAMPLE Ten subjects (N = 20 ears) were recruited who were experienced users of behind-the-ear hearing aids with conventional vented earmolds and had bilateral sensorineural hearing loss that was >30 dB HL below 1000 Hz and ≤70 dB HL to 4000 Hz. DATA COLLECTION AND ANALYSIS Real-ear in-situ thresholds (dB sound pressure level [SPL]) and real-ear aided responses (REAR; dB SPL) were measured at 500, 1000, 2000, and 4000 Hz to determine differences in SL between SoundTracker, Verifit, and 6500. A three-factor repeated measures analysis of variance (ANOVA) was utilized to determine differences between method (real-ear analyzers and SoundTracker), analyzer (Verifit and 6500), and frequency (500, 1000, 2000, and 4000 Hz). RESULTS Mean differences in measured SL for the Verifit and 6500 were ≤2 dB when compared to the estimated SL using SoundTracker. A statistically significant difference in SL was present between the Verifit and SoundTracker at 2000 Hz (p < 0.01), but no significant differences were present at 500, 1000, and 4000 Hz. A statistically significant difference in SL was present between the 6500 and SoundTracker at 4000 Hz (p < 0.01), but no significant differences were present at 500, 1000, and 2000 Hz. Mean differences in measured SL between the real-ear analyzers (difference of SoundTracker SL minus Verifit SL compared to the difference of SoundTracker SL minus 6500 SL) were ≤2 dB with a statistically significant difference present at 2000 Hz (p < 0.01), but no statistically significant differences were present at 500, 1000, or 4000 Hz. CONCLUSIONS Nearly 85% of the differences between the estimated SoundTracker SL and the measured SLs of the Verifit and 6500 were ≤2 dB. Despite some limitations of this study, SoundTracker could be useful as a counseling tool to illustrate to patients which sounds are audible or inaudible when unaided and aided.
منابع مشابه
Conformity of the real-ear aided response with the target response from the DSL v5 formula
Objectives: Real ear measurement plays a critical role in children’s hearing aid fitting. This study aimed to evaluate the conformity of measured and predicted real-ear aided response (REAR) of prescribed formula desired sensation level (DSL) v5 Pediatric in children aged 4 to 7 years. Since there is limited information about the effect of the degree of hearing loss (DOHL), ethnicity, gender, a...
متن کاملVerification of in situ thresholds and integrated real-ear measurements.
BACKGROUND Accurate prescriptive gain results in a more accurate fit, lower return rate in hearing aids, and increased patient satisfaction. In situ threshold measurements can be used to determine required gain. The Widex Corporation uses an in situ threshold measurement strategy, called the Sensogram. Real-ear measurements determine if prescriptive gain targets have been achieved. Starkey Labo...
متن کاملمقایسه سطح هیجانخواهی، راهبردهای مقابلهای و میزان آسیبپذیری در برابر استرس در بین معتادان تحت درمان نگهدارنده با متادون و افراد سالم
Introduction: The purpose of this research was to investigate the relationship between the level of sensation seeking and coping strategies as well as vulnerability to stress among addicts who are under MMT treatment and normal group. Method: This research was a causal comparative study. The population of the study was all addicts of Baharestan city of Esfahan province who were referred to addi...
متن کاملبررسی رابطه بین هیجانخواهی و میزان رضایت زناشویی
The purpose of the present study was to investigate the relationship between sensation seeking and: marital satisfaction, gender, education, marital duration and age differences of the couples. The subjects were 200 couples who were randomly selected among, Arak city families through a two- stage sampling method. The research measurement instruments were: Zuckerman's Sensation Seeking Scale fo...
متن کاملCompare emotional and social maturity and sensation seeking in adolescents and ordinary criminals Khorramabad
This study aimed to compare the emotional and social maturity and sensation seeking adolescents delinquent boys and normal in Khorramabad. The population consists of all juvenile in center reform that 23 were selected and equal with 23 based on sampling. In this study variables were measured by Bhargava Yashvyrsyng emotional maturity, social maturity Rao questionnaire and Zuckerman Sensation ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Academy of Audiology
دوره 24 8 شماره
صفحات -
تاریخ انتشار 2013