Differences in metal ion release following cobalt-chromium and oxidized zirconium total knee arthroplasty.

نویسندگان

  • Simon Garrett
  • Neal Jacobs
  • Piers Yates
  • Anne Smith
  • David Wood
چکیده

Ions are released from all metals after implantation in the body through processes of corrosive and mechanical wear. The aim of this study was to investigate whether serum metal ion levels are raised in patients following total knee arthroplasty. Serum levels of chromium, cobalt, aluminium, molybdenum and zirconium were measured in two groups of patients at a minimum of 3 years after knee arthroplasty. Twenty three patients had a cobalt-chromium femoral component and 14 patients had an oxidized zirconium femoral component, acting as a control group as this femoral component is free from cobalt and chromium. All patients had the same titanium tibial base plates, and no patellae were resurfaced. Despite the lack of cobalt and chromium in the prostheses used in the control group, no statistically significant differences in serum cobalt and chromium ion levels were found between the groups. On the basis of these results there does not appear to be any significant rise in serum metal ion levels following total knee arthroplasty several years after implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Five-year comparison of oxidized zirconium and cobalt-chromium femoral components in total knee arthroplasty: a randomized controlled trial.

BACKGROUND In vitro analysis has shown that oxidized zirconium on ultra-high molecular weight polyethylene has better wear properties than cobalt-chromium on ultra-high molecular weight polyethylene. The purpose of this study was to determine if oxidized zirconium femoral components performed better than cobalt-chromium in vivo and if the use of oxidized zirconium components had clinical advers...

متن کامل

Revision of a tibial baseplate using a customized oxinium component in a case of suspected metal allergy. A case report.

Materials currently used for total knee arthroplasty (TKA) are well known for their good biocompatibility, but corrosion of the implant and metal ion release may elicit an immune response in the periprosthetic tissue. Its role in the outcome of the implant remains a subject of discussion. Metal sensitivity after joint replacement is frequent, but few patients exhibit symptoms. Nickel, cobalt an...

متن کامل

Metal sensitivity in patients before and after total knee arthroplasty (TKA): comparison between ceramic surfaced oxidized zirconium and cobalt-chromium implants

Backgrounds: The purpose of this study was to investigate clinical relevance of preoperative screening for metal sensitivity (MS), and to assess whether there is any difference in the MS after total knee arthroplasty (TKA) between oxidized zirconium (OxZr) and cobalt-chrome (Co-Cr) implants. Methods: A total of 48 subjects referred for TKA were enrolled the study with no history of metal allerg...

متن کامل

Ten-Year Comparison of Oxidized Zirconium and Cobalt-Chromium Femoral Components in Total Knee Arthroplasty

This open-access article is published and distributed under the Creative Commons Attribution NonCommercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article witho...

متن کامل

Abrasion resistance of oxidized zirconium in comparison with CoCrMo and titanium nitride coatings for artificial knee joints.

Most total knee replacement joints consist of a metal femoral component made from a cobalt-chromium- molybdenum (CoCrMo)-alloy and a tibial component with an ultrahigh molecular weight polyethylene (UHMWPE) bearing surface. Wear of the UHMWPE remains the primary disadvantage of these implants. The allergic potential ascribed to CoCrMo-alloys is a further concern. Other metallic alloys with and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 76 4  شماره 

صفحات  -

تاریخ انتشار 2010