Highly sensitive determination method for total carbonate in water samples by flow injection analysis coupled with gas-diffusion separation.

نویسندگان

  • M Oshima
  • Y Wei
  • M Yamamoto
  • H Tanaka
  • T Takayanagi
  • S Motomizu
چکیده

A spectrophotometric method for the determination of total carbonate in water samples was developed. The method is based on the color change of an acid-base indicator in relation to the concentration of permeable gas substances through a membrane. By using a new portable FIA system equipped with a gas-diffusion unit, a highly sensitive and on-site determination of total carbonate in aqueous solutions was investigated. A new color-change system with 4-(2',4'-dinitrophenylazo)-1-naphthol-5-sulfonic acid (DNN5S) was developed. Absorbance changes of the reagent solution were measured at 450 nm with a light-emitting diode (LED) as a light source. A new type of gas-diffusion unit was used, and was constructed with double tubing: the inner tubing was a micro porous PTFE (polytetrafluoroethylene) tubing (1.0 mm inner diameter and 1.8 mm outer diameter, pore size 2 microns, porosity 50%); the outer tubing was made of glass with 2.0 mm inner diameter. The optimized system conditions were as follows: the sample size was 200 microliters, the temperature of the air bath for the gas-diffusion unit was 25 degrees C, and the length of the gas-diffusion unit was 15 cm; each flow rate was 0.3 ml min-1. For measuring carbonate at low concentrations, a method for preparing water with less carbonate was proposed: the carbonate content of the water was decreased down to 5 x 10(-7) M. The calibration graph was rectilinear from 1 x 10(-6) M to 10(-3) M, and the detection limit (corresponding to a signal-to-noise ratio of 3) was 1 x 10(-6) M of carbonate. The relative standard deviation (RSD) of ten measurements of 2.3 x 10(-5) M Na2CO3 solution was 1.9%. The total carbonate in various kinds of water (such as river, sea, rain, distilled and ultra purified) was determined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implication of an Integrated Approach to the Determination of Water Saturation in a Carbonate Gas Reservoir Located in the Persian Gulf

Water saturation determination is one of the most important tasks in reservoir studies to predict oil and gas in place needed to be calculated with more accuracy. The estimation of this important reservoir parameter is commonly determined by various well logs data and by applying some correlations that may not be so accurate in some real practical cases, especially for carbonate reservoirs. Sin...

متن کامل

A Developed Electromembrane Technique Based on Flat Electrospun Membrane Coupled with Gas-chromatography for the Determination of Phthalates in Different Water Samples

In this work, we successfully developed electromembrane extraction via preparation of an electrospun flat membrane based on device. The polyurethane-membrane was prepared by electrospinning method and used in EME. Affecting parameters on membrane preparation were optimized by Taguchi design. The developed method was used for extraction of phthalates as typical molecules and the proposed method ...

متن کامل

Development and application of a robust speciation method for determination of six arsenic compounds present in human urine.

Six arsenic species [arsenate, arsenite, arsenocholine, arsenobetaine, monomethyl arsonic acid, and dimethyl arsinic acid] present in human urine were determined using ion-exchange chromatography combined with inductively coupled plasma mass spectrometry (IC-ICP-MS). Baseline separation was achieved for all six species as well as for the internal standard (potassium hexahydroxy antimonate V) in...

متن کامل

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Flow injection conductometric system with gas diffusion separation for the determination of Kjeldahl nitrogen in milk and chicken meat.

A simple flow injection (FI) conductometric system with gas diffusion separation was developed for the determination of Kjeldahl nitrogen (or proteins) in milk and chicken meat. The sample was digested according to the Kjeldahl standard method and the digest was diluted and directly injected into the donor stream consisting of 4M NaOH. In alkaline medium, ammonium was converted to ammonia, whic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 17 11  شماره 

صفحات  -

تاریخ انتشار 2001