The efficacy of a computerized caries detector in intraoral digital radiography.
نویسنده
چکیده
BACKGROUND A unique software tool has been developed to assist dentists in the difficult task of diagnosing radiographs for proximal caries. The software, called Logicon Caries Detector (Northrop Grumman Information Technology, Herndon, Va.), extracts image features and correlates them with a database of known caries problems. The Logicon software was combined with the digital radiography system Trophy RadioVisioGraphy (Trophy Radiologie, Croissy-Beaubourg, France) and its effectiveness was measured in a clinical study, the results of which are reported here. METHODS The manufacturer trained 18 dentists in private practices and one university clinic across the United States to use the Logicon Caries Detector software. The dentists diagnosed 175 surfaces with potential caries and adjacent teeth expected to be clean but included as control surfaces. The dentists first did a visual diagnosis only and then repeated the diagnosis using the software. If their final diagnosis called for it, a restoration was performed and the depth of caries was recorded. RESULTS Effectiveness was gauged by calculating three measures of performance-sensitivity, specificity and accuracy-for dentin caries diagnosis by each dentist both before and after using Logicon Caries Detector. Sensitivity among all dentists before using the Logicon software was 70.3 percent and afterward was 90.5 percent, an improvement of 20.2 percent. Dentists' specificity was 88.6 percent before using the software and 88.3 percent afterward, with a difference of-0.3 percent. Dentists' accuracy was 75.6 percent before using the software and 88.3 percent afterward, with an improvement of 12.7 percent. CONCLUSIONS Logicon Caries Detector enabled dentists to find 20 percent more cases of caries penetrating into dentin than they were able to find without it, while not causing them to mistreat any additional healthy teeth. CLINICAL IMPLICATIONS Digital radiography and smart software like Logicon Caries Detector will improve dentists' diagnostic abilities and lead to better patient care.
منابع مشابه
Efficacy of Pseudocolor Tool of Digital System in the Detection of Proximal Caries
Introduction: Various intraoral digital radiographic systems are available as an alternative to film-based radiography. Recent rapid progress in the field of digital radiography offers the possibility of image processing and manipulation. Pseudocolor filter is one of the tools of digital systems. The aim of this study was to compare diagnostic accuracy of proximal caries in black and white a...
متن کاملIn vitro Comparison of Conventional Film and Direct Digital Radiography in Proximal Caries Detection
Introduction: Various systems for intraoral digital radiography have been available as an alternative to film–based radiography. In consideration of several advantages of digital radiography such as less patient absorbed dose, manipulation of image quality and elimination of processing, it has been extensively used in different fields of dentistry in recent years. The purpose of this study wa...
متن کاملبررسی دقت پانورامیک دیجیتال در تشخیص پوسیدگیهای پروگزیمال
Background and Aims: Conventional radiological equipments in our country are going to be converted to digital system using computed radiology (CR) technology. If we know the accuracy of digital panoramic radiography for detection of small defects in tooth, it will be useful in cases with difficulty for taking the intraoral radiographs. The aim of this study was to evaluate sensitivity and speci...
متن کاملComparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)
Background and Aim: Considering the importance of detection of secondary caries, the adverse consequences of false positive and false negative diagnoses and the gap of information in the diagnostic efficacy of digital sensors in detection of secondary caries, this in vitro study sought to compare the diagnostic efficacy of two different resolutions of radiographs obtained by photostimulable pho...
متن کاملComparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects
Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects. Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...
متن کاملThe Comparison between Two Different Digital Panoramic Radiography Techniques in the Detection of Proximal Caries
Introduction: Although proximal dental caries are very common, clinical examinations cannot detect them all. Panoramic radiography has been widely used in dentistry for both diagnosis and screening. This study aimed to investigate and compare the efficacy of two digital panoramic radiography techniques in the diagnosis of proximal caries. Methods: A total number of 60 patients referred to a den...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Dental Association
دوره 133 7 شماره
صفحات -
تاریخ انتشار 2002