Investigation of the Actual Causes of Hip Joint Implant Loosening Classified as Aseptic--Analysis of Microbiological Culture Results and Levels of Inflammatory Markers.

نویسندگان

  • Dagmara Strzelec-Nowak
  • Maria Kozioł-Montewka
  • Justyna Niedźwiadek
  • Agnieszka Bogut
  • Jan Blacha
  • Tomasz Mazurkiewicz
چکیده

Loosening of the hip joint prosthesis is considered as one of the most significant postoperative complications in recent years. The laboratory diagnostic procedure used to differentiate periprosthetic infection from aseptic loosening is very difficult because of the biofilm which microorganisms form on the implant surface. The purpose of this research was to evaluate the level of concordance between clinical classification of implant loosening among 50 patients subjected to reimplantation procedure and laboratory investigation of PJI including microbiological culture results and the levels of inflammatory markers assessed in the patients' synovial fluid samples, serum, and full blood. The synovial fluid was collected for leukocyte count, differential cell count, and culture on standard media. The levels of systemic inflammation markers such as the ESR and CRP concentration were determined in serum and full blood. Tissue samples were collected for microbiological studies. Components from endoprostheses were exposed to ultrasound in a process called sonication. Among the parameters measured in serum and full blood the levels of ESR and CRP were higher in the septic group of patients. Cytologic analysis of synovial fluid was in correlation with microbiologic identification. The most frequent isolated bacteria was Staphylococcus epidermidis. Culture results from materials such as synovial fluid, sonicate and tissues are crucial to establish the infectious aetiology of the loosening. Microscopic analysis of synovial fluid represents a simple, rapid and accurate method for differentiating PJI from aseptic failure. Sonication increases detection of the infectious process, and culture results are in correlation with the cytologic analysis of synovial fluid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Particle Disease: A Current Review of the Biological Mechanisms in Periprosthetic Osteolysis After Hip Arthroplasty

BACKGROUND Inflammatory responses to wear debris cause osteolysis that leads to aseptic prosthesis loosening and hip arthroplasty failure. Although osteolysis is usually associated with aseptic loosening, it is rarely seen around stable implants. Aseptic implant loosening is a simple radiologic phenomenon, but a complex immunological process. Particulate debris produced by implants most commonl...

متن کامل

Different Profiles of Toll-like Receptors (TLRs) Expressions in Aseptic Loose Periprosthetic Tissues and Septic Synovial Membranes around Total Hip Implants

INTRODUCTION: Total hip replacement (THR) is a procedure that reliably provides pain relief and improves daily activity for patients suffering from destructive end stage hip joint disease. The main long-term complication of THR surgery is prosthetic loosening often combined with osteolysis. The causes of loosening are mainly divided into two major categories. One is the septic loosening caused ...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Long Term Outcomes of Total Hip Arthroplasty in Young Patients under 30

Background:  We aimed to report outcomes of total hip arthroplasty (THA) in very young patients under the year of 30.   Methods:  Thirty patients (45 hips) with various indications for THA were retrospectively reviewed radiologically and clinically and analyzed regarding survival, reasons of failure, factors associated with outcomes and postoperative complications.   Results:  Within a mean fol...

متن کامل

Male gender, Charnley class C, and severity of bone defects predict the risk for aseptic loosening in the cup of ABG I hip arthroplasty

BACKGROUND We studied which factor could predict aseptic loosening in ABG I hip prosthesis with hydroxyapatite coating. Aseptic loosening and periprosthetic osteolysis are believed to be caused, at least in part, by increased polyethylene (PE) wear rate via particle disease. Based on it, increased PE wear rate should be associated with aseptic loosening regardless of the type of implant. METH...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Polish journal of microbiology

دوره 64 2  شماره 

صفحات  -

تاریخ انتشار 2015