Heart failure reversal by ventricular unloading in patients with chronic cardiomyopathy: criteria for weaning from ventricular assist devices
نویسندگان
چکیده
AIMS Unloading-promoted reversal of heart failure (HF) allows long-term transplant-free outcome after ventricular assist device (VAD) removal. However, because few patients with chronic cardiomyopathy (CCM) were weaned from VADs (the majority only recently), the reliability of criteria used for weaning decisions to predict long-term post-weaning success is barely known. After 15 years of weaning experience, we assessed this issue. METHODS AND RESULTS In 47 patients with CCM as the underlying cause for HF, who were part of a total of 90 patients weaned from bridge-to-transplant-designed VADs since 1995, we analysed data on cardiac morphology and function collected before VAD implantation, echocardiographic parameters recorded during 'off-pump' trials, duration of HF before implantation, and stability of recovery before and early after VAD removal. Post-weaning 5 year freedom from HF recurrence reached 66%. Only five patients (10.6%) died due to HF recurrence or weaning-related complications. Pre-explantation off-pump left ventricular ejection fraction (LVEF) of ≥50 and ≥45% revealed predictive values for cardiac stability lasting ≥5 years after VAD removal of 91.7 and 79.1%, respectively. With each unit of LVEF reduction, the risk of HF recurrence became 1.5 times higher. The predictive value of LVEF ≥45% also became >90% if additional parameters like pre-explantation LV size and geometry, stability of unloading-induced cardiac improvement before VAD removal, and HF duration before VAD implantation were also considered. Definite cut-off values for certain parameters (including tissue-Doppler-derived LV wall motion velocity) allowed formulation of weaning criteria with high predictability for post-weaning stability, also in patients with incomplete cardiac recovery. CONCLUSIONS Ventricular assist device removal in CCM patients is feasible and can be successful even after incomplete cardiac recovery. Parameters of pre-explantation cardiac function, LV size and geometry, their stability during final off-pump trials, and HF duration allow detection of patients with the potential to remain stable for >5 post-weaning years.
منابع مشابه
Myocardial recovery during mechanical circulatory support: long-term outcome and elective ventricular assist device implantation to promote recovery as a treatment goal
Even after incomplete myocardial recovery during mechanical circulatory support, long-term survival rates after ventricular assist device (VAD) explantation can be better than those expected after heart transplantation even for patients with chronic non-ischemic cardiomyopathy as the underlying cause for VAD implantation. The elective therapeutic use of ventricular assist devices for heart fail...
متن کاملPrediction of cardiac stability after weaning from left ventricular assist devices in patients with idiopathic dilated cardiomyopathy.
BACKGROUND During ventricular assist device (VAD) unloading, cardiac recovery is possible even in patients with chronic heart failure (HF). We sought parameters predictive of cardiac stability after VAD removal. METHODS AND RESULTS Among 81 patients weaned since March 1995, a homogenous group of 35 with idiopathic dilated cardiomyopathy weaned from left VADs was selected. We evaluated echo da...
متن کاملMyocardial recovery in peri-partum cardiomyopathy after continuous flow left ventricular assist device
Left ventricular assist devices (LVADs) offer effective therapy for severe heart failure (HF) as bridge to transplantation or destination therapy. Rarely, the sustained unloading provided by the LVAD has led to cardiac reverse remodelling and recovery, permitting explantation of the device. We describe the clinical course of a patient with severe peri-partum cardiomyopathy (PPCM) rescued with a...
متن کاملCellular, molecular, genomic changes occurring in the heart under mechanical circulatory support.
Heart failure (HF) is a clinical syndrome that arises from any functional or structural impairment of one or two ventricles in either filling or ejection of blood. The clinical syndrome of HF results from disorders of the pericardium, myocardium, endocardium, heart valves or metabolic abnormalities, and manifests itself mainly as impaired left ventricular (LV) myocardial function (1). The clini...
متن کاملLong-term results in patients with idiopathic dilated cardiomyopathy after weaning from left ventricular assist devices.
BACKGROUND Since our first successful left ventricular assist device (LVAD) explantation in a patient with idiopathic dilated cardiomyopathy (IDCM) in 1995, an additional 31 IDCM patients have been weaned in our department. Echocardiographic evaluations during repeated "off-pump" trials were the cornerstone for weaning decisions. After 9 years of experience, we assessed the reliability of our w...