Effects of bone oscillator coupling method, placement location, and occlusion on bone-conduction auditory steady-state responses in infants.

نویسندگان

  • Susan A Small
  • Jennifer L Hatton
  • David R Stapells
چکیده

OBJECTIVE The aim of these experiments was to investigate procedures used when estimating bone-conduction thresholds in infants. The objectives were: (i) to investigate the variability in force applied using two common bone-oscillator coupling methods and to determine whether coupling method affects threshold estimation, (ii) to examine effects of bone-oscillator placement on bone-conduction ASSR thresholds, and (iii) to determine whether the occlusion effect is present in infants by comparing bone-conduction ASSR thresholds for unoccluded and occluded ears. DESIGN Experiment 1A: The variability in the amount of force applied to the bone oscillator by trained assistants (n = 4) for elastic-band and hand-held coupling methods was measured. Experiment 1B: Bone-conduction behavioral thresholds in 10 adults were compared for two coupling methods. Experiment 1C: ASSR thresholds and amplitudes to multiple bone-conduction stimuli were compared in 10 infants (mean age: 17 wk) using two coupling methods. Experiment 2: Bone-conduction ASSR thresholds and amplitudes were compared for temporal, mastoid and forehead oscillator placements in 15 preterm infants (mean age: 35 wk postconceptual age (PCA)). Experiment 3: Bone-conduction ASSR thresholds, amplitudes and phase delays were compared in 13 infants (mean age: 15 wk) for an unoccluded and occluded test ear. All infants that participated had passed a hearing screening test. RESULTS Experiment 1A: Coupling method did not significantly affect the variability in force applied to the oscillator. Experiment 1B: There were no differences in adult bone-conduction behavioural thresholds between coupling methods. Experiment 1C: There was no significant difference between oscillator coupling method or significant frequency x coupling method interaction for ASSR thresholds or amplitudes in the young infants tested. However, there was a nonsignificant 9-dB better threshold at 4000 Hz for the elastic-band method. Experiment 2: Mean bone-conduction ASSR thresholds for the preterm infants were not significantly different for the temporal and mastoid placements. Mean ASSR thresholds for the forehead placement were significantly higher compared to the other two placements (12-18 dB higher on average). Mean ASSR amplitudes were significantly larger for the temporal and mastoid placements compared to the forehead placement. Experiment 3: There was no difference in mean ASSR thresholds, amplitudes or phase delays for the unoccluded versus occluded conditions. CONCLUSIONS Trained assistants can apply an appropriate amount of force to the bone oscillator using either the elastic-band or hand-held method. Coupling method has no significant effect on estimation of bone-conduction thresholds; therefore, either may be used clinically provided assistants are appropriately trained. For preterm infants, there are no differences in ASSRs when the oscillator is positioned at the temporal or mastoid placement. However, thresholds are higher and amplitudes are smaller for the forehead placement, consequently, a forehead placement should be avoided for clinical testing. There does not appear to be a significant occlusion effect in young infants; therefore, it may be possible to do bone-conduction testing with ears unoccluded or occluded without applying a correction factor, although further research is needed to confirm this finding.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal ipsilateral/contralateral asymmetries in infant multiple auditory steady-state responses to air- and bone-conduction stimuli.

OBJECTIVES Two-channel recordings of infants' air- and bone-conduction auditory brainstem responses to brief tones show ipsilateral and contralateral (to the stimulated ear) asymmetries which may be used to isolate which cochlea is the primary contributor to the response. The objective of this study was to determine whether similar ipsilateral/contralateral asymmetries are also present in the a...

متن کامل

[Multiple auditory steady-state responses to bone conduction stimuli].

OBJECTIVE To assess the accuracy of threshold using the multiple auditory steady state responses (MASSR) to bone conduction stimuli in a group of patients with conductive hearing loss. METHOD Thirty patients with conductive hearing loss were assessed by MASSR and by pure-tone audiometry, and compared the results of these two methods. RESULT The thresholds of MASSR and those of PTA were sign...

متن کامل

The auditory steady-state response: clinical observations and applications in infants and children.

Two studies illustrate the use of the auditory steady-state response (ASSR) in the pediatric clinical audiology setting. A protocol for estimating bone-conduction thresholds from ASSR was developed. Bone-conducted narrow-band noise was used to mask the ASSR for a 1.0-kHz modulated tone. The amount of bone-conducted noise needed to mask the ASSR may distinguish between infants and children with ...

متن کامل

Hearing screening using auditory steady state responses obtained by simultaneous air- and bone-conduction stimuli.

INTRODUCTION AND OBJECTIVES Minimising false positives rates is an important goal of universal newborn hearing screening programmes. An adequate way for reaching that goal could be differentiating between transient conductive hearing losses (false positives) and permanent sensorineural hearing impairments (true positives) by means of a methodology that studies electrophysiological responses obt...

متن کامل

Hearing sensitivity in newborns estimated from ABRs to bone-conducted sounds.

This study focused on the problem of estimating hearing sensitivity in newborns from auditory brainstem responses (ABRs) evoked by clicks and 500 Hz and 4000 Hz tonebursts presented by a bone-conduction (BC) oscillator. The effects of acoustic energy transmitted to the ear canal, gender, and ear differences were also investigated. ABR thresholds for BC stimuli were 56, 52, and 53 dB (re 1 micro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ear and hearing

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 2007