Manipulation of DNA origami nanotubes in liquid using programmable tapping- mode atomic force microscopy
نویسندگان
چکیده
Longhai Li1,2, Xiaojun Tian1, Zaili Dong1, Lianqing Liu1, Osamu Tabata3,4, Wen J. Li1,5 State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, People’s Republic of China University of Chinese Academy of Sciences, Beijing, People’s Republic of China Department of Micro Engineering, Kyoto University, Kyoto, Japan Freiburg Institute for Advanced Studies (FRIAS), University of Freiburg, Freiburg, Germany Deparment of Mechanical and Biomedical Engineering, City University of Hong Kong, Hong Kong, People’s Republic of China E-mail: [email protected]
منابع مشابه
Sensitivity Analysis of Frequency Response of Atomic Force Microscopy in Liquid Environment on Cantilever's Geometrical Parameters
In this paper, the non-linear dynamic response of rectangular atomic force microscopy in tapping mode is considered. The effect of cantilever’s geometrical parameters (e.g., cantilever length, width, thickness, tip length and the angle between the cantilever and the sample's surface in liquid environment has been studied by taking into account the interaction forces. Results indicate that the r...
متن کاملTapping mode atomic force microscopy in liquid
We show that standard silicon nitride cantilevers can be used for tapping mode atomic force microscopy (AFM) in air, provided that the energy of the oscillating cantilever is sufficiently high to overcome the adhesion of the water layer. The same cantilevers are successfully used for tapping mode AFhif in liquid. Acoustic modes in the liquid excite the canti1eve.r. On soft samples, e.g., biolog...
متن کاملFrequency and force modulation atomic force microscopy: low-impact tapping-mode imaging without bistability
Since the 1980s, atomic force microscopy (AFM) has rapidly developed into a versatile, high-resolution characterization technique, available in a variety of imaging modes. Within intermittent-contact tapping-mode, imaging bistability and sample mechanical damage continue to be two of the most important challenges faced daily by AFM users. Recently, a new double-control-loop tapping-mode imaging...
متن کاملNonlinear tapping dynamics of multi-walled carbon nanotube tipped atomic force microcantilevers
The nonlinear dynamics of an atomic force microcantilever (AFM) with an attached multi-walled carbon nanotube (MWCNT) tip is investigated experimentally and theoretically. We present the experimental nonlinear frequency response of a MWCNT tipped microcantilever in the tapping mode. Several unusual features in the response distinguish it from those traditionally observed for conventional tips. ...
متن کامل