Evolution of Cyclophotocoagulation

نویسندگان

  • Jideofor K. Ndulue
  • Kamran Rahmatnejad
  • Carina Sanvicente
  • Sheryl S. Wizov
  • Marlene R. Moster
چکیده

Cyclodestructive techniques have been a treatment option for refractory glaucoma since its first use in the 1930s. Over the past nine decades, cyclodestruction has advanced from the initial cyclodiathermy to micropulse transscleral cyclophotocoagulation (MP-TSCPC) which is the current treatment available. Complications associated with cyclodestruction including pain, hyphema, vision loss, hypotony and phthisis have led ophthalmologists to shy away from these techniques when other glaucoma treatment options are available. Recent studies have shown encouraging clinical results with fewer complications following cyclophotocoagulation, contributing greatly to the current increase in the use of cyclophotocoagulation as primary treatment for glaucoma. We performed our literature search on Google Scholar Database, Pubmed, Web of Sciences and Cochrane Library databases published prior to September 2017 using keywords relevant to cyclodestruction, cyclophotocoagulation and treatment of refractory glaucoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neodymium-YAG transscleral cyclophotocoagulation. The role of pigmentation.

Using a rabbit model we investigated the role of pigmentation of the ciliary body in obtaining ciliodestruction by neodymium-YAG transscleral cyclophotocoagulation. There was marked destruction of the ciliary body in pigmented rabbit eyes, but no histologic effect was observed in albino rabbit eyes. These findings suggest that pigmentation of the ciliary body is important for obtaining the desi...

متن کامل

Long-Term Outcome of Transscleral Diode Laser Cyclophotocoagulation for Refractory Glaucoma

Objective: To study success rate and long term efficacy and complications of the transscleral diode laser Cyclophotocoagulation in refractory glaucoma. Patients and Methods: In a noncomparative interventional case series, eyes of 9 patients with glaucoma resistant to conventional medical and surgical therapies were treated with transscleral diode laser Cyclophotocoagulation from 2004 to 2007. C...

متن کامل

Evaluation of cyclophotocoagulation effects with 1310-nm contact optical coherence tomography.

PURPOSE The aim of this pilot study was to evaluate whether contact optical coherence tomography (OCT) allows visualization of the effects of cyclophotocoagulation. METHODS In this pilot study, transscleral contact OCT images (1310-nm wavelength) were generated prior to and immediately after conventional transscleral diode laser cyclophotocoagulation in three eyes of three patients who were s...

متن کامل

Micropulse versus continuous wave transscleral diode cyclophotocoagulation in refractory glaucoma: a randomized exploratory study.

BACKGROUND The aim of this study was to compare the efficacy and safety of micropulse and continuous wave diode transscleral cyclophotocoagulation in refractory glaucoma. DESIGN Randomized, comparative, exploratory study in a tertiary hospital setting. PARTICIPANTS Patients with refractory, end-stage glaucoma. METHODS Forty-eight patients were randomized to either treatment. The intraocul...

متن کامل