Quantitative impact of Dixon μmap variability in dual-time-point brain PET/MR
نویسندگان
چکیده
Center for Biomedical Imaging, Department of Radiology, NYU Langone Medical Center, New York, USA Dixon-based MR is acquired for attenuation correction of brain PET during PET/MR. Early adopters of PET/MR have noted variability in the performance of Dixon-based tissue segmentation, and questions exist regarding potential impacts on quantitative accuracy in dual-time-point studies. Ten patients injected with 10 mCi FDG underwent dual-time-point clinical brain PET/MR on a Siemens mMR, with image reconstructions based on data acquired at 45 – 60 and 75 – 90 minutes. Dixon μmaps were obtained the time of FDG injection and at 75 minutes. 8 cc of Gadavist was injected for post-contrast MR at 30 minutes. Subjects were removed from the table and repositioned prior to the 75 minute scan. The delayed μmap was registered to the original μmap using MIMneuro. The aligned image data was copied onto the original μmap DICOM file using Matlab. Early time-point PET data was reconstructed using both the early and delayed μmaps. Atlas-based segmentation was performed to compare regional SUV values. When comparing the delayed versus original μmap reconstructions, regional SUV values varied on average by +1.9% for both SUVmax and SUVmean. For large brain structures, SUVmax and SUVmean varied by -0.5% to +5.6% and -0.2 to +4.7%, respectively. For deep brain structures, SUVmax using the delayed reconstruction varied by -0.5% to +3.7% and SUVmean varied by -0.3% to +3.6%. Most differences in SUV were higher when using the delayed μmap. There is variability in regional SUV values for brain PET data reconstructed using two different aligned Dixon acquisitions performed on subjects undergoing repeat same-day PET/MR imaging, with SUV values ~2% higher using the delayed μmap. This variability may impact results in dual-time-point brain PET/MR.
منابع مشابه
Attenuation Correction for Brain PET imaging using Deep Neural Network based on Dixon and ZTE MR images
Positron Emission Tomography (PET) is a functional imaging modality widely used in neuroscience studies. To obtain meaningful quantitative results from PET images, attenuation correction is necessary during image reconstruction. For PET/MR hybrid systems, PET attenuation is challenging as Magnetic Resonance (MR) images do not reflect attenuation coefficients directly. To address this issue, we ...
متن کاملA hybrid method for generation of attenuation map for MR-based attenuation correction of PET data in prostate PET/MR imaging
Department of Medical Physics and Biomedical Engineering and Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran Recently introduced PET/MRI scanners present significant advantages in comparison with PET/CT. However, the lack of accurate method for generation of μmap from MR images for implementation of MRAC is hampering further development. I...
متن کاملImpact of incorrect tissue classification in Dixon-based MR-AC: fat-water tissue inversion
BACKGROUND The current MR-based attenuation correction (AC) used in combined PET/MR systems computes a Dixon attenuation map (MR-ACDixon) based on fat and water images derived from in- and opposed-phase MRI. We observed an occasional fat/water inversion in MR-ACDixon. The aim of our study was to estimate the prevalence of this phenomenon in a large patient cohort and assess the possible bias on...
متن کاملMR-based attenuation correction using ultrashort-echo-time pulse sequences in dementia patients.
UNLABELLED Attenuation correction (AC) is a critical requirement for quantitative PET reconstruction. Accounting for bone information in the attenuation map (μ map) is of paramount importance for accurate brain PET quantification. However, to measure the signal from bone structures represents a challenging task in MR. Recent (18)F-FDG PET/MR studies showed quantitative bias for the assessment o...
متن کاملReproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System
The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET)-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic parameters as a function of PET system choice have been investigated. Five healthy volunteers underwent dyn...