Metal-on-metal hip resurfacing with an uncemented femoral component. A seven-year follow-up study.

نویسندگان

  • Thomas P Gross
  • Fei Liu
چکیده

BACKGROUND Metal-on-metal hip resurfacing with hybrid fixation has been introduced as an alternative to standard total hip arthroplasty, especially for young and active patients. There are few studies in the literature on the midterm results of cementless femoral side resurfacing. The purpose of this study was to present our seven-year clinical results of a series of twenty cementless metal-on-metal hip resurfacing procedures. METHODS Between 1999 and 2000, eighteen patients (twenty hips) underwent primary metal-on-metal hip resurfacing with uncemented femoral and acetabular components. One patient was lost to follow-up. This left eleven men and six women, who had a mean age of forty-five years at the time of surgery. Clinical and radiographic examinations were performed prospectively, and the results were analyzed. RESULTS The mean duration of follow-up was 7.4 years. There were four revisions, none of which was due to aseptic failure of the femoral component. Two were due to loosening of the acetabular component, one was due to a late hematogenous infection, and one was due to persistent pain despite normal radiographic findings. The mean preoperative Harris hip score was 54 points, and it increased to 94 points at the time of the last follow-up. Radiographic examination of the hips for which the procedure was successful revealed no femoral or acetabular radiolucencies, no migration of any implant, and no osteolysis. The radiographs of one patient (two hips) showed substantial narrowing of the femoral necks (a mean of 12%), which stabilized at three years postoperatively. This patient had a Harris hip score of 100 points for both hips at six years. CONCLUSIONS This study suggests that cementless femoral fixation may be a viable alternative to fixation with cement in metal-on-metal hip resurfacing. Further study of this concept in larger numbers of patients is warranted.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The first 100 fully porous-coated femoral components in hip resurfacing.

UNLABELLED Uncemented fixation of implants to bone is a proven technology in traditional hip arthroplasty surgery. However, cement fixation is currently the standard method for the femoral component in hip resurfacing. The purpose of this study was to evaluate the performance of uncemented fixation of the femoral component in the first 100 fully porous-coated metal-on-metal hip resurfacing arth...

متن کامل

Mortality rates at 10 years after metal-on-metal hip resurfacing compared with total hip replacement in England: retrospective cohort analysis of hospital episode statistics

OBJECTIVES To compare 10 year mortality rates among patients undergoing metal-on-metal hip resurfacing and total hip replacement in England. DESIGN Retrospective cohort study. SETTING English hospital episode statistics database linked to mortality records from the Office for National Statistics. POPULATION All adults who underwent primary elective hip replacement for osteoarthritis from ...

متن کامل

Comparison of fully porous-coated and hybrid hip resurfacing: a minimum 2-year follow-up study.

The purpose of this study was to compare clinical and radiological outcomes of the first 191 fully porous-coated hip resurfacing arthroplasties with 96 hybrid hip resurfacing arthroplasties performed during the same period at a minimum 2-year follow-up to evaluate the initial fixation of uncemented femoral resurfacing components. The results of this study indicate that fully porous-coated femor...

متن کامل

Clinical and radiological outcome of stemmed hip replacement after revision from metal-on-metal resurfacing.

We report the outcome of total hip replacement in 29 failed metal-on-metal resurfacing hip replacements in which the primary surgery was performed between August 1995 and February 2005. The mean length of follow-up was five years (1.7 to 11.7). Of the 29 hip resurfacings, 19 acetabular components and all the femoral components were revised (28 uncemented stems and one cemented stem). There were...

متن کامل

A prospective randomized clinical trial comparing metal-on-metal total hip arthroplasty and metal-on-metal total hip resurfacing in patients less than 65 years old.

The purpose of this prospective randomised study is to compare the early clinical results of the metal-on-metal hip resurfacing to metal-on-metal THA. Two hundred and ten hips were randomised between August 2003 and January 2006 (191 subjects). One hundred and two hips were implanted with an uncemented titanium tapered stem, and an uncemented titanium acetabular component and 28 mm metal-on-met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 90 Suppl 3  شماره 

صفحات  -

تاریخ انتشار 2008