Long-range diffusion of hyperpolarized 3He in normal and emphysematous rat lungs
نویسندگان
چکیده
Introduction: Diffusion weighted imaging and in particular the apparent diffusion coefficient (ADC) are among the main lung gas MRI applications. Since ADC values are related to molecular mobility, they are expected to reflex changes in lung microstructure, and hence be used as a detector for early stage lung diseases. Long-range diffusion can instead provide information about the microstructural sizes and connectivity of the lung airspaces. The main aim of this work was to measure long-range ADC in rats in a single-lobe model of emphysema, at breath-hold and end expiration. Methods: The left lobe of the lung of 10 Wistar rats were instilled with 25 units of porcine pancreatic elastase dissolved in a volume of 0.1ml/100g animal weight. Five of these animals were measured six weeks after the instillation and another three animals were imaged seven weeks after the instillation. Prior to imaging, animals were anaesthetized with thiopental sodium, intubated and connected to a mechanical ventilator, which ventilated animals at 60bpm with a mixture consisting of 21% O2 and 79% He. The ventilator also applied a bolus of HP-gas to reach a full-inspiration of 25mbar of pressure. A 10s-breath-hold was applied to the animals in the acquisition mode. Animals were imaged during the breath-hold at 25mbar and also at the end of the expiration following the application of a short full-inspiration, they are denoted as BH and EEV, respectively. The gas applied for imaging consisted of 77% HPHe and 23% N2. This mixture was prepared in order to avoid the effect of having different diffusion coefficients due to having different gases. The image data were acquired with a Bruker Biospec 70/20 spectrometer operated at 0.5T. A stimulated echo spiral sequence [1] was used to obtain diffusion images with 2 b-values (0 and 7.16 s·cm) and diffusion time of 1 second. Results: Figure 1 shows the ADC mean values obtained from the left (elastase-treated) lobe and from the right (control) lobe of the rat lung measured under the two ventilation conditions, BH of 25 mbar and EEV. One of the EEV datasets was found to be unusable after post-processing. The error bars represent the standard deviation of ADC of the eight and seven animals, respectively. This figure shows significant differences between the two lobes at 25mbar fullinspiration breath-hold (P < 0.001) with a remarkable increase in the ADC value for the emphysematous lobe. However, this effect was not seen when animals were imaged at the end of the expiration. At EEV, both the emphysematous and the normal lobe show a relatively high ADC. Figure 2 represents one of the ADC maps obtained at full-inspiration breath-hold. It shows by the scale of colour the different values of ADC. Discussion: Elastase treated lungs show a larger ADC when measured at breath-hold than healthy lungs. No statistically significant difference was seen when the measurement is performed at EEV. The origin of this difference is unknown, but it could be due to a remodelling of the lung, this is, an increase in collateral ventilation[2]. Why this effect is not seen at EEV cannot yet be explained. Collateral paths offer a parallel set of routes for long-range diffusivity that avoid the tortuous paths that follow the airways. In emphysema, tissue destruction occurs with an increase of collateral paths[3]. If collateral paths consist of interalveolar pores, then a hypothesis could be that these pores have a greater size at breath-hold, when the pressure of the lung is higher. If this were the case, however, ADC at EEV would be much lower. An increase in ADC in long-range diffusion in emphysematous lungs has been seen, as well, in studies in dogs[4] and human lungs[5]. In this sense, the ADC increase seen at breath-hold for emphysematous lungs is consistent with those previous studies.
منابع مشابه
Long-range diffusion of hyperpolarized 3He in explanted normal and emphysematous human lungs via magnetization tagging.
Long-range diffusivity of hyperpolarized 3He gas was measured from the decay rate of sinusoidally modulated longitudinal nuclear magnetization in three normal donor and nine severely emphysematous explanted human lungs. This (long-range) diffusivity, which we call Dsec, is measured over seconds and centimeters and is approximately 10 times smaller in healthy lungs (0.022 cm2/s) than the more tr...
متن کاملLong-range diffusion of hyperpolarized He in explanted normal and emphysematous human lungs via magnetization tagging
Woods, Jason C., Dmitriy A. Yablonskiy, Cliff K. Choong, Kimiaki Chino, John A. Pierce, James C. Hogg, John Bentley, Joel D. Cooper, Mark S. Conradi, and Peter T. Macklem. Long-range diffusion of hyperpolarized He in explanted normal and emphysematous human lungs via magnetization tagging. J Appl Physiol 99: 1992–1997, 2005. First published July 14, 2005; doi:10.1152/japplphysiol.00185.2005.—Lo...
متن کاملInnovative Methodology Long-range diffusion of hyperpolarized He in explanted normal and emphysematous human lungs via magnetization tagging
Woods, Jason C., Dmitriy A. Yablonskiy, Cliff K. Choong, Kimiaki Chino, John A. Pierce, James C. Hogg, John Bentley, Joel D. Cooper, Mark S. Conradi, and Peter T. Macklem. Long-range diffusion of hyperpolarized He in explanted normal and emphysematous human lungs via magnetization tagging. J Appl Physiol 99: 1992–1997, 2005. First published July 14, 2005; doi:10.1152/japplphysiol.00185.2005.—Lo...
متن کاملProton and hyperpolarized helium magnetic resonance imaging of radiation-induced lung injury in rats.
PURPOSE To assess the usefulness of hyperpolarized helium (3He) MRI, including apparent diffusion coefficient measurements, in the detection and evaluation of radiation-induced lung injury in rats. METHODS AND MATERIALS Female Fischer-344 rats were treated to the right lung with fractionated dose of 40 Gy (5 x 8 Gy) using 4-MV photons. Conventional proton (1H) and hyperpolarized (3He) MRI wer...
متن کاملEmphysematous changes and normal variation in smokers and COPD patients using diffusion 3He MRI.
INTRODUCTION This study aims to quantify global and regional changes of diffusive motion of 3He gas within the lung, as determined by hyperpolarized 3He MR apparent diffusion coefficient (ADC) measurement, in non-smokers, smokers and chronic obstructive pulmonary disease (COPD) patients. METHODS Age-matched groups of six healthy non-smokers, five healthy smokers and five patients with COPD. T...