Individual Optimization of the Insertion of a Preformed Cochlear Implant Electrode Array

نویسندگان

  • Thomas S. Rau
  • Thomas Lenarz
  • Omid Majdani
چکیده

Purpose. The aim of this study was to show that individual adjustment of the curling behaviour of a preformed cochlear implant (CI) electrode array to the patient-specific shape of the cochlea can improve the insertion process in terms of reduced risk of insertion trauma. Methods. Geometry and curling behaviour of preformed, commercially available electrode arrays were modelled. Additionally, the anatomy of each small, medium-sized, and large human cochlea was modelled to consider anatomical variations. Finally, using a custom-made simulation tool, three different insertion strategies (conventional Advanced Off-Stylet (AOS) insertion technique, an automated implementation of the AOS technique, and a manually optimized insertion process) were simulated and compared with respect to the risk of insertion-related trauma. The risk of trauma was evaluated using a newly developed "trauma risk" rating scale. Results. Using this simulation-based approach, it was shown that an individually optimized insertion procedure is advantageous compared with the AOS insertion technique. Conclusion. This finding leads to the conclusion that, in general, consideration of the specific curling behaviour of a CI electrode array is beneficial in terms of less traumatic insertion. Therefore, these results highlight an entirely novel aspect of clinical application of preformed perimodiolar electrode arrays in general.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan

Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...

متن کامل

The internal dimensions of the cochlear scalae with special reference to cochlear electrode insertion trauma.

HYPOTHESIS To investigate the intracochlear micromorphology with regard to frequent patterns of cochlear electrode insertion trauma. OBJECTIVE Cochlear implantation is a widely accepted treatment for deafness and high-grade sensorineural hearing loss. Although the device and the implantation methods are continuously optimized, damage of intracochlear structures due to electrode insertion is a...

متن کامل

Path Planning and Workspace Determination for Robot-Assisted Insertion of Steerable Electrode Arrays for Cochlear Implant Surgery

In previous works, the authors showed that using robot-assisted steerable electrode array insertions can significantly reduce the insertion forces compared to non-steerable electrode arrays. In addition to steering the electrode array, it is possible to change its angle of approach with respect to the scala tympani. This paper focuses on determining the relevance of changing the angle of approa...

متن کامل

An overview of cochlear implant electrode array designs

Cochlear implant electrode arrays are designed with specific characteristics that allow for the preservation of intra-cochlear structures during the insertion process, as well as during explantation. Straight lateral wall (LW) electrode arrays and pre-curved modiolar hugging (MH) electrode arrays are the two types that are commercially available. Although there is a third type of electrode arra...

متن کامل

Active positioning device for a perimodiolar cochlear electrode array

The authors report on an actuated positioning device for a cochlear prosthesis insertion procedure. The device consists of multiple high-aspect ratio fluidic actuator chambers integrated with a high-density silicon cochlear electrode array and manufactured in a taperedhelix form. Actuation chambers with cross-sectional sizes as small as 40 · 200 lm and lengths of 30 mm have been fabricated usin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015