Purge- and intensive-purge decontamination of dental units contaminated with biofilm
نویسندگان
چکیده
INTRODUCTION During hygienic-microbiological monitoring of the water quality in dental units, the total bacterial colony count was found to exceed the limits for drinking water quality; in addition, mold contamination was detected. The presumed cause was irregular decontamination of the units through purging and intensive decontamination. METHODS To decontaminate the units, the manufacturer's recommended program for cleaning and intensive decontamination was intensified by shortened intervals over a 2-week period. For Sirona units, instead of once a day, the automatic purge program was run every morning and evening for 20 min each time, and instead of once a month, intensive decontamination was performed every two weeks; this schedule has been maintained since then. For KaVo units, cleaning with the hydroclean function was carried out for 2.5 min every morning and evening. The automatic intensive decontamination was run daily instead of weekly. A maintenance log book was introduced, in which decontamination/cleaning was confirmed by the operator's signature. RESULTS Within 5 weeks, all previously contaminated units were decontaminated. DISCUSSION By shortening the cleaning and intensive decontamination intervals in a 2-week period with subsequent control that the recommended maintenance intervals were kept, it was possible to guarantee drinking-water quality in the dental units of both manufacturers.
منابع مشابه
Evaluation of the PotoClean® decontamination technology for reprocessing of water supply lines in dental units during routine work
BACKGROUND A frequent problem in dental units is the microbial contamination of water and biofilm formation in the water supply lines. After random identification of a bacterial contaminated dental unit (310 cfu/ml) in a practise with 3 dental units we implemented the present study to evaluate the efficacy of the PotoClean(®) technology, based on anodic oxidation. METHOD The efficacy of a reg...
متن کاملMicrobial quality of water in dental unit waterlines
BACKGROUND Dental unit waterlines (DUWLs) are ideal environment for development of microbial biofilms. Microbial contamination of water in DUWLs is thought to be the result of biofilm formation as it could serves as a haven for pathogens. The aim of this study was to assess microbial quality of water in dental unit waterlines of dental units located at the dental school of Isfahan University of...
متن کاملInvestigation of purge time in cathodic dead-end mode PEMFC
Recently, special type of fuel cells has been developed that operates in a Dead End mode. Working in this condition, the Dead-End fuel cell is supplied withhydrogen almost at the same rate of consumption. It is noteworthy to mention thatall of the water transport mechanisms have been considered in this simulation.Water accumulation that is directly proportional to the cell current is of a grea...
متن کاملDraft: Optimization of Purge Cycle for Dead-ended Anode Fuel Cell Operation
This paper focuses on the optimization of the purge cycle for dead-ended anode (DEA) operation of a proton exchange membrane (PEM) fuel cell. Controling the purge interval at given operating conditions can optimize the fuel cell efficiency and hydrogen loss during the purge. For this optimization, a model capturing the liquid water and nitrogen accumulation in the anode and the purge flow behav...
متن کاملErrors in flow and pressure related to the arterial filter purge line.
The purge line is a necessary component on arterial filters, although its presence may affect the amount of flow reaching the patient as well as the pump outlet pressure in the extracorporeal circuit. In-vitro and clinical studies conducted to investigate these effects with a commonly used purge line showed that at flows less than 1.5 L/min, rates for pediatric or infant patients, the purge lin...
متن کامل