Operating theatre ventilation systems and microbial air contamination in total joint replacement surgery: results of the GISIO-ISChIA study.
نویسندگان
چکیده
BACKGROUND Recent studies have shown a higher rate of surgical site infections in hip prosthesis implantation using unidirectional airflow ventilation compared with turbulent ventilation. However, these studies did not measure the air microbial quality of operating theatres (OTs), and assumed it to be compliant with the recommended standards for this ventilation technique. AIM To evaluate airborne microbial contamination in OTs during hip and knee replacement surgery, and compare the findings with values recommended for joint replacement surgery. METHODS Air samplings were performed in 28 OTs supplied with unidirectional, turbulent and mixed airflow ventilation. Samples were collected using passive sampling to determine the index of microbial air contamination (IMA). Active sampling was also performed in some of the OTs. The average number of people in the OT and the number of door openings during the sampling period were recorded. FINDINGS In total, 1228 elective prosthesis procedures (60.1% hip and 39.9% knee) were included in this study. Of passive samplings performed during surgical activity in unidirectional airflow ventilation OTs (U-OTs) and mixed airflow OTs (M-OTs), 58.9% and 87.6% had IMA values >2, respectively. Of samplings performed during surgical activity in turbulent airflow OTs (T-OTs) and in turbulent airflow OTs with the surgical team wearing Steri-Shield Turbo Helmets (TH-OTs), 8.6% and 60% had IMA values ≤ 2, respectively. Positive correlation was found between IMA values and the number of people in the OT and the number of door openings (P < 0.001). In addition, correlation was found between active and passive sampling (P < 0.001). CONCLUSION These findings challenge the belief that unidirectional systems always provide acceptable airborne bacterial counts.
منابع مشابه
Sterile Parts of Operating Gown during Lower Limb Joint Replacement Surgery
Background: The prevention of surgical site infection is one of the most concerning issues in operating rooms. Surgicalgowns are worn as one of the intraoperative strategies for infection prevention. The present study investigated whetherthe gowns remained sterile during the surgical procedure. Furthermore, this study examined which parts of the surgicalgown were more prone to...
متن کاملCan Particulate Air Sampling Predict Microbial Load in Operating Theatres for Arthroplasty?
Several studies have proposed that the microbiological quality of the air in operating theatres be indirectly evaluated by means of particle counting, a technique derived from industrial clean-room technology standards, using airborne particle concentration as an index of microbial contamination. However, the relationship between particle counting and microbiological sampling has rarely been ev...
متن کاملCost Effectiveness of Laminar Flow Systems for Total Shoulder Arthroplasty: Filtering Money from the OR?
Background: Laminar flow ventilation systems were developed to reduce surgical contamination in joint arthroplastyto avoid periprosthetic joint infection (PJI). The goals of this study are to evaluate the cost-effectiveness and economicviability of installing and maintaining a laminar flow system in an operating room.Methods: A Monte Carlo simulation was used to evaluate the c...
متن کاملRisk of surgical site infections following hip and knee arthroplasty: results of the ISChIA-GISIO study.
BACKGROUND Surgical Site Infection (SSI) is one of the major complications following insertion of hip or knee prosthesis. The aim of the present study was to describe rates of SSIs and associated risk factors during hip and knee prosthesis procedures in Italian hospitals. METHODS Italian hospitals were invited to join the ISChIA (Surgical Site Infections in Arthroplasty Surgery) project and p...
متن کاملForced-air warming and ultra-clean ventilation do not mix: an investigation of theatre ventilation, patient warming and joint replacement infection in orthopaedics.
We investigated the capacity of patient warming devices to disrupt the ultra-clean airflow system. We compared the effects of two patient warming technologies, forced-air and conductive fabric, on operating theatre ventilation during simulated hip replacement and lumbar spinal procedures using a mannequin as a patient. Infection data were reviewed to determine whether joint infection rates were...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of hospital infection
دوره 90 3 شماره
صفحات -
تاریخ انتشار 2015