Separation of proteins and peptides by capillary electrophoresis in acid buffers containing high concentrations of surfactants.
نویسندگان
چکیده
Separations of proteins at acid pH in the presence of a high concentration of surfactant [sodium laurylsulfate (SDS), 50 mmol/l] was investigated. The purpose of using high concentrations of SDS as background electrolyte modifier was threefold: First, the surfactant exerts a washing effect upon the capillary wall thus preventing binding of analytes and possible clogging of the capillary. Second, it was revealed that even under very acid conditions (below pH 3) the surfactant is capable of forming associates with protein analytes which still bear considerable negative charge and can be separated on this basis. Third, the system can be applied not only for protein mixtures sufficiently soluble in neutral to alkaline media (leukocyte lysates, standard proteins), but it can be used also with proteins, that are under such conditions virtually insoluble and their solubilization is possible in acid buffers only (eggshell proteins or collagen CNBr fragments). The result was that adsorption to the capillary wall was minimized and the analytes were separated as negatively charged associates with high efficiency. With collagen fragments partition was possible on the affinity differences of the peptides to the surfactant micelles and inner wall of the capillary. Theoretical plate counts approaching 100,000 were easily achieved even with proteins which under the more conventional operation conditions exhibit considerable sticking to the capillary wall. The other feature of this system is that the associates move very rapidly to the anode. Owing to the low pH, endoosmotic flow is negligible, and therefore the system has to be operated at reversed polarity.
منابع مشابه
Capillary electrophoretic separation of proteins and peptides by ion-pairing with heptanesulfonic acid.
Heptanesulfonic acid as ion-pairing agent was used for the separation of mixtures of low and high molecular mass peptides/proteins by capillary electrophoresis. The separation conditions used were: capillary 37 cm (30 cm to the detector) x 75 microm i.d., voltage 10 kV, phosphate buffer 50 mmol/l, ion-pairing agent heptanesulfonic acid at three different concentrations, namely, 0, 20 or 100 mmo...
متن کاملCapillary zone electrophoresis of collagen type I CNBr peptides in acid buffers.
Collagen type-I CNBr peptides were separated under acidic conditions by capillary electrophoresis. Separation conditions were: 100 mM phosphate buffer pH 2.5, 50 cm x 50 microns capillary (placed in a cartridge), 8 kV, running time 30-45 min, detection by UV at 200 nm. The peptides were separated strictly by their molecular mass and the overall pattern was well comparable to RP-HPLC separations...
متن کاملChiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis
Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...
متن کاملEffect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection
Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...
متن کاملChiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis
Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 852 1 شماره
صفحات -
تاریخ انتشار 1999