Evaluation of AISI Type 304 stainless steel as a suitable surface material for evaluating the efficacy of peracetic acid-based disinfectants against Clostridium difficile spores

نویسندگان

  • Elaine Black
  • Krista Owens
  • Richard Staub
  • Junzhong Li
  • Kristen Mills
  • Justin Valenstein
  • John Hilgren
چکیده

Disinfectants play an important role in controlling microbial contamination on hard surfaces in hospitals. The effectiveness of disinfectants in real life can be predicted by laboratory tests that measure killing of microbes on carriers. The modified Quantitative Disk Carrier Test (QCT-2) is a standard laboratory method that employs American Iron and Steel Institute (AISI) Type 430 stainless steel carriers to measure hospital disinfectant efficacy against Clostridium difficile spores. The formation of a rust-colored precipitate was observed on Type 430 carriers when testing a peracetic acid (PAA)-based disinfectant with the QCT-2 method. It was hypothesized that the precipitate was indicative of corrosion of the Type 430 carrier, and that corrosion could impact efficacy results. The objective of this study was to compare the suitability of AISI Type 430 to Type 304 stainless steel carriers for evaluating PAA-based disinfectants using the QCT-2 method. Type 304 is more corrosion-resistant than Type 430, is ubiquitous in healthcare environments, and is used in other standard methods. Suitability of the carriers was evaluated by comparing their impacts on efficacy results and PAA degradation rates. In efficacy tests with 1376 ppm PAA, reductions of C. difficile spores after 5, 7 and 10 minutes on Type 430 carriers were at least about 1.5 log10 lower than reductions on Type 304 carriers. In conditions simulating a QCT-2 test, PAA concentration with Type 430 carriers was reduced by approximately 80% in 10 minutes, whereas PAA concentration in the presence of Type 304 carriers remained stable. Elemental analyses of residues on each carrier type after efficacy testing were indicative of corrosion on the Type 430 carrier. Use of Type 430 stainless steel carriers for measuring the efficacy of PAA-based disinfectants should be avoided as it can lead to an underestimation of real life sporicidal efficacy. Type 304 stainless steel carriers are recommended as a suitable alternative.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Sporicidal Activity of Disinfectants against Clostridium difficile and Bacillus amyloliquefaciens Spores by Using the Improved Methods Based on ASTM E2197-11

Spore-forming pathogenic bacteria, such as Clostridium difficile, are associated with nosocomial infection, leading to the increased use of sporicidal disinfectants, which impacts socioeconomic costs. However, C. difficile can be prevented using microorganisms such as Bacillus amyloliquefaciens, a prophylactic agent that has been proven to be effective against it in recent tests or it can be co...

متن کامل

Antimicrobial efficacy of copper surfaces against spores and vegetative cells of Clostridium difficile: the germination theory.

OBJECTIVES Persistent contamination of surfaces by spores of Clostridium difficile is a major factor influencing the spread of C. difficile-associated diarrhoea (CDAD) in the clinical setting. In recent years, the antimicrobial efficacy of metal surfaces has been investigated against microorganisms including methicillin-resistant Staphylococcus aureus. This study compared the survival of C. dif...

متن کامل

Efficacy of three surface disinfectants against spores of Clostridium difficile ribotype 027.

BACKGROUND The emergence of Clostridium difficile ribotype 027 raised the question of sporicidal surface disinfectants are also effective against spores of C. difficile ribotype 027. MATERIALS AND METHODS Three surface disinfectants based on magnesium monoperoxyphthalate hexahydrate (Dismozon pur), a combination of (ethylenedioxy)dimethanol, glutaral and benzyl-C12-18-alkyldimethylammonium ch...

متن کامل

Activity of disinfectants against foodborne pathogens in suspension and adhered to stainless steel surfaces

The purpose of this study was to investigate and compare the efficacy of various disinfectants on planktonic cells and biofilm cells of Listeria monocytogenes, Staphylococcus aureus and Escherichia coli. Numbers of viable biofilm cells decreased after treatment with all tested disinfectants (iodine, biguanide, quaternary ammonium compounds, peracetic acid and sodium hypochlorite). Sodium hypoch...

متن کامل

Inactivation of an enterovirus by airborne disinfectants

BACKGROUND The activity of airborne disinfectants on bacteria, fungi and spores has been reported. However, the issue of the virucidal effect of disinfectants spread by fogging has not been studied thoroughly. METHODS A procedure has been developed to determine the virucidal activity of peracetic acid-based airborne disinfectants on a resistant non-enveloped virus poliovirus type 1. This viru...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017