Unexpected bioprosthetic mitral valve thrombus during left ventricular assist device implantation
نویسندگان
چکیده
Acute bioprosthetic valve thrombosis can occur after surgery and sometimes cause hemodynamic instability and cardiogenic shock. Risk factors for bioprosthetic valve thrombosis are hypercoagulability, atrial fibrillation, atrial dilatation, low cardiac function, and lack of anticoagulation therapy. The authors present a case of severe mitral stenosis due to bioprosthetic valve thrombus. The patient was diagnosed with dilated-phase hypertrophic cardiomyopathy and underwent mitral valve replacement. He required venoarterial extracorporeal membrane oxygenation (VA-ECMO) due to extremely low cardiac output and was scheduled for left ventricular assist device (LVAD) implantation. Transesophageal echocardiographic examination before LVAD implantation revealed severe mitral stenosis due to bioprosthetic mitral valve thrombus, which was not detected by transthoracic echocardiography in the intensive care unit and contributed to the low cardiac function. The thrombus was removed through an unscheduled left atriotomy before LVAD implantation. The possibility of bioprosthetic valve thrombosis must be considered when the patient is dependent on VA-ECMO support. Early transesophageal echocardiographic examination of the bioprosthetic valve may be helpful and contribute to surgical decision-making.
منابع مشابه
First-in-Human Experience With Transcatheter Mitral Valve-in-Valve Implantation During Left Ventricular Assist Device Placement.
Valvular disease is common in patients undergoing left ventricular assist device (LVAD) implantation. Concomitant valve surgery increases procedural complexity and cardiopulmonary bypass time and may lead to worse outcomes. Although mitral regurgitation is the most common mitral valve dysfunction in patients undergoing LVAD implantation, mitral stenosis (MS) is occasionally encountered. MS can ...
متن کاملBioprosthetic mitral valve thrombosis less than one year after replacement and an ablative MAZE procedure: a case report
Occurrence of bioprosthetic valve thrombosis less than a year after replacement is very uncommon. Here, we describe a case of a 57 year old male, who presented 10 months after receiving a bioprosthetic mitral valve replacement with a two week history of dyspnea on exertion, worsening orthopnea and decreased exercise tolerance. Echocardiography revealed severe mitral regurgitation (MR), thrombos...
متن کاملBioprosthetic mitral valve thrombosis. Importance of transesophageal echocardiography in the diagnosis and follow-up after treatment.
OBJECTIVE To report the clinical and echocardiographic findings of bioprosthetic mitral valve thrombosis and the value of transesophageal echocardiography (TEE) in its diagnosis and monitoring of thrombolysis. METHODS One hundred and eleven patients with mitral bioprostheses underwent TEE, and 4 out of 7 suspected of having a thrombus on these prostheses were included in the study (mean age =...
متن کاملUse of Cardiac Computerized Tomography to Predict Neo–Left Ventricular Outflow Tract Obstruction Before Transcatheter Mitral Valve Replacement
A lthough the incidence of mitral stenosis has declined precipitously in the Western world due to the reduced incidence of rheumatic heart disease, mitral regurgitation remains one of the most common valvular pathologies. Many patients affected by severe mitral valve disease are elderly with multiple comorbidities and are at high risk for traditional open surgical mitral valve repair or replace...
متن کاملThrombus in Ventricular Assist Device Patients
Background. Thromboembolic events may be related to thrombotic deposition on prosthetic valves. In a left ventricular assist device (LVAD) that contains two porcine pericardial bioprosthetic valves in addition to significant associated biomaterial placement, this may be particularly true. Thrombotic deposits on valves removed from LVADs at autopsy or heart transplantation were scored to determi...
متن کامل