False-negative thermonuclease tests with new BacTAlert blood culture bottles.

نویسندگان

  • L D Tilson
  • P D Midolo
  • T G Kerr
چکیده

The Microbiology Unit of Southern Cross Pathology Australia, Monash Medical Centre, has used the Organon Technika BacTAlert automated blood culture instrument since 1995 for the detection of causative organisms of septicemia and bacteremia. When a blood culture bottle is flagged as positive, it is removed from the instrument and subculturing and Gram staining are performed. Gram-positive cocci, which morphologically resemble staphylococci, are tested by the thermostable nuclease (TSN) method (1) for rapid differentiation of Staphylococcus aureus from coagulase-negative staphylococci. The results are available after 2, 4, or 24 h of incubation at 35°C. We have used this test for the past 6 years and have found it to be reliable and rapid in the determination of significant isolates from blood cultures. Clinicians use the test results to decide whether to commence immediate antibiotic therapy. Organon Technika recently replaced its blood culture bottles with a new line of ventless bottles. From March of this year until now, we have had five types of this new series of bottles in use at our hospital. These are the pediatric PF bottle, the aerobic FA and anaerobic FN bottles, and the standard aerobic and anaerobic bottles. Since these new bottles have been in circulation, it has been noted that a number of false-negative TSN results have been obtained. That is, the TSN reaction was negative at 2, 4, and 24 h while the S. aureus latex test (SSI Systems) and later DNase testing of the cultured organism yielded positive results. In June and July 2001, 23.5% (4 of 17 isolates) and 14% (5 of 36 isolates) of isolates, respectively, produced false-negative TSN results, which was evident when S. aureus was seen upon Gram staining and subsequently cultured. On two of these occasions, repeat testing by the TSN method was performed and the results remained the same. This is disturbing, given that until recently the TSN method was very reliable. No false-negative or false-positive results had previously been reported at Southern Cross Pathology Australia. In the article by Forward et al. (1), the sensitivity of the TSN test was reported to be 92.6% and the negative predictive value was reported to be 97.9%. All of the recent false-negative results were obtained with the new ventless bottles, including the pediatric PF bottle, the aerobic and anaerobic (FA and FN) bottles, and a standard (vent-less) aerobic bottle. The error was further highlighted in one case when a standard (vented) bottle and a FA (ventless) bottle from the same patient were flagged as positive on the same day. The results of testing by the TSN method were positive for the vented bottle and negative for the ventless bottle concurrently. We have also observed that the zone sizes of samples positive for TSN are noticeably smaller than those of a given positive control. Previously, the TSN zone size under test was similar in diameter to that of the positive control, ranging from 26 to 28 mm. A survey of the new ventless bottles revealed the average zone size was 14 mm compared to 26 mm for the positive control. One isolate from a continuous ambulatory peritoneal dialysis patient was thought to have a false-positive result. The S. aureus latex test and the DNase test yielded negative results, and subsequent identification confirmed that the isolate was Staphylococcus schleiferi. This organism is known to be thermonuclease positive. In conclusion, we have been unable to determine the cause of the observed false-negative reaction. It appears to be unpredictable: some strains of S. aureus from the new bottles are TSN positive while others are TSN negative. However, until further research is done, it is evident that some caution should be taken when interpreting the results of the TSN test for isolates of gram-positive cocci morphologically resembling staphylococci from these new ventless bottles from Organon Technika.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Problems of thermonuclease detection for identifying Staphylococcus aureus in blood culture broths.

The detection of thermonuclease by the Oxford strain and eight clinical isolates of Staphylococcus aureus in a variety of bacteriological broths with and without added blood was examined using a toluidine blue-DNA-agar plate method. In Isosensitest, brain-heart infusion, tryptic soy, nutrient and gas-liquid chromatography broths (all of which do not contain liquoid) thermonuclease detection was...

متن کامل

Blood culture volume and detection of coagulase negative staphylococcal septicaemia in neonates.

A prospective, blind study was carried out to determine: the amount of blood submitted for culture from neonates; whether small blood volumes resulted in false negative results; and whether there was a temporal relation between volume of blood cultured and time to positivity. Seventy three bottles were evaluated. They contained a median of 0.63 ml of blood. Twenty nine bottles (39.7%) contained...

متن کامل

Controlled clinical comparison of VersaTREK and BacT/ALERT blood culture systems.

To assess the relative yields in automated microbial detection systems of bacteria and yeasts isolated from the blood of adult patients with suspected sepsis, we compared the new VersaTREK system (VTI) (TREK Diagnostic Systems, Cleveland, OH) to the BacT/ALERT 3D system (3D) (bioMérieux, Inc., Durham, NC). Identical protocols were followed for the two systems. Paired aerobic (REDOX 1) and anaer...

متن کامل

Rapid identification of Staphylococcus aureus in blood cultures by thermonuclease testing.

The detection of thermonuclease activity in 86 blood culture samples containing gram-positive cocci showed 100% correlation with the subsequent identification of the isolate as Staphylococcus aureus by the coagulase test. No positive thermonuclease results were found with 66 samples containing coagulase-negative staphylococci and 56 samples containing other gram-positive organisms. The thermonu...

متن کامل

False-negative culture results with fungal isolates from peritoneal dialysis fluid.

Recently, newly reported causes of fungal peritonitis associated with continuous ambulatory peritoneal dialysis were described both in this journal and in another (6, 7). These episodes threatened to go undetected due to false-negative culture results in the initial investigations. Each of these cases involved inoculation of peritoneal dialysis (PD) fluid into BACTEC (Becton Dickinson) blood cu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 39 11  شماره 

صفحات  -

تاریخ انتشار 2001