Current opinions about coronal plane alignment in total knee arthroplasty: A survey article.
نویسندگان
چکیده
PURPOSE To survey an audience of international knee surgeons about their current opinions on the analysis of coronal knee alignment and their objectives for postoperative alignment in total knee arthroplasty. METHODS Survey of 300 surgeons from 32 different countries with an audience response system allowing three possible answers being either a positive or negative answer or an abstention. RESULTS Surveyed surgeons perform rarely preoperative and postoperative full leg radiographs and evaluate radiological outcomes more with short films. The main trend in this survey was towards neutral mechanical alignment, however varus alignment is acceptable in constitutional varus patients. This residual varus should be obtained through a femoral varus cut rather than a tibial varus cut. The valgus knee can remain in slight valgus but most of the correction will be performed at the femoral level. The main objective of postoperative alignment in TKA is a joint line parallel to the floor and a central load-bearing axis through the middle of the arthroplasty. Surgeons prefer unicompartmental arthroplasty more for themselves than for their patients in case of medial bone on bone arthritis. CONCLUSIONS Neutral mechanical axis with a joint line parallel to the floor and a centrally running load bearing axis remains the central scope of the surveyed surgeons. Because of the literature on residual varus it becomes more acceptable for the orthopaedic community to accept this type of outlier before aiming at a surgical correction.
منابع مشابه
Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...
متن کاملThe current role of coronal plane alignment in Total Knee Arthroplasty in a preoperative varus aligned population: an evidence based review.
BACKGROUND Based on historical data, the current standard of care in Total Knee Arthroplasty (TKA) is to restore the overall alignment to a neutral mechanical axis of 0°±3° or even slight valgus. However, there is significant controversy in literature regarding intentionally placing the TKA in the patient's physiologic, rather than neutral (0±3°), mechanical alignment. QUESTIONS/PURPOSES The ...
متن کاملThe Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty
Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...
متن کاملReview article: Patient-specific versus standard instrumentation for total knee arthroplasty.
This meta-analysis reviewed 12 studies comparing patient-specific instrumentation (PSI) with standard instrumentation (SI) for total knee arthroplasty in terms of postoperative coronal alignment and operation time. There is no significant difference between PSI and SI in terms of hip-knee-ankle angle (overall coronal alignment or mechanical axis), tibial coronal alignment, and operation time.
متن کاملRadiographic results of an accelerometer-based, handheld surgical navigation system for the tibial resection in total knee arthroplasty.
In total knee arthroplasty (TKA), intramedullary and extramedullary tibial alignment guides are not proven to be highly accurate in obtaining alignment perpendicular to the mechanical axis in the coronal plane. The objective of this study was to determine the accuracy of an accelerometer-based, handheld surgical navigation system in obtaining a postoperative tibial component alignment within 2°...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 81 3 شماره
صفحات -
تاریخ انتشار 2015