Reliability and minimal detectable change of three functional tests: forward-lunge, step-up-over and sit-to-stand

نویسندگان

  • Carmen Luque-Siles
  • Tomas Gallego-Izquierdo
  • Jose Jesus Jímenez-Rejano
  • Susana Granados de-la-Orden
  • Gustavo Plaza-Manzano
  • Africa López-Illescas-Ruiz
  • Alejandro Ferragut-Garcías
  • Natalia Romero-Franco
  • Patricia Martín-Casas
  • Daniel Pecos-Martín
چکیده

[Purpose] To examine the intrasession and intersession reliability and the absolute reliability of three functional dynamic tests-forward-lunge, step-up-over and sit-to-stand tests-using computerized dynamic posturography. [Subjects and Methods] An intra-test and test-retest, repeated measure study was designed. Forty-five healthy subjects twice carried out the forward-lunge test, step-up-over test, and sit-to-stand test on two days, one week apart. The intrasession and intersession reliabilities as judged by the intraclass correlation coefficient (ICC) and the minimal detectable change of the three functional tests were calculated. [Results] Excellent to very good intrasession reliability of the forward-lunge test (ICC range of 0.9-0.8) was found. Very good to good intrasession reliability of the step-up-over test (ICC range of 0.9-0.5) was found and very good intrasession reliability of the sit-to-stand test (ICC range of 0.8-0.7) was found. The minimal detectable change at the 95% confidence level of most of the measures was lower than 30%. [Conclusion] The forward-lunge, step-up-over and sit-to-stand tests are reliable measurement tools.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Test-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects

  Abstract   Background: Postural instability has been identified as a potential precursor of   falls in elderly subjects. Postural stability in quiet stance is commonly assessed with   center of pressure (COP) measures. The purpose of this study was to determine testretest reliability and minimal detectable change (MDC) for the center of pressure   (COP) measures in the elderly subjects.   Met...

متن کامل

Reliability and validity of Alternate Step Test times in subjects with chronic stroke.

OBJECTIVE (i) To investigate the intra-rater, inter-rater and test-retest reliability and minimal detectable change of the Alternate Step Test (AST) when assessing people with chronic stroke. (ii) To quantify the correlation between AST times and stroke-specific impairments. DESIGN Cross-sectional study. SETTING University-based rehabilitation centre. PARTICIPANTS A convenience sample of ...

متن کامل

پایایی آزمون-بازآزمون، روایی سازه و همخوانی درونی نسخه فارسی‌شده آزمون «مقیاس تعادل پیشرفته فولرتون» در سالمندان ایرانی مقیم جامعه

Objectives: This study was performed to evaluate convergent validity, test-retest reliability and internal consistency of the Persian translation of the Fullerton advanced balance (FAB) for use in Iranian community- dwelling older adults and improve the quality of their functional balance assessment. Methods & Materials: The original scale was translated with forward-backward protoco...

متن کامل

The effect of dual task training on sit to stand postural control of elderly women with a history of falling

The purpose of the present study was to investigate the effect of dual task training including balance sit-to-stand and cognitive exercises on postural control of sit to stand of elderly women with a history of falling. 15 elderly women were randomly divided into control (n=7) and experimental (n=8) groups. Participants implemented training protocol for four weeks in both experimental (balance ...

متن کامل

The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke

Purpose: The first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. The Fugl-Meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. The present study aimed to investigate the test-retest reliability and minimal detectable change (MDC) in these tw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2016