Fabrication and field emission property of a Si nanotip array.
نویسندگان
چکیده
Using a Si-based porous anodic alumina membrane as a mask, we demonstrate a way to pattern Si surface. After removing the SiO(2) nanoislands formed during anodization of the Al/Si interface, we obtain a Si nanotip array on the surface of a Si wafer. This array shows an excellent field emission property with a low turn-on field of 8.5 V µm(-1). The Fowler-Nordheim plot obtained is linearly dependent, indicating that the emission current arises from the quantum tunnelling effect. The Si nanotip array can be expected to have important applications in nanoelectronic devices.
منابع مشابه
Fabrication and characterization of well-aligned and ultra-sharp silicon nanotip array
Well-defined, uniform, and large-area nanoscaled tips are of great interest for scanning probe microscopy and high-efficiency field emission. An ultra-sharp nanotip causes higher electrical field and, hence, improves the emission current. In this paper, a large-area and well-aligned ultra-sharp nanotip arrays by reactive ion etching and oxidation techniques are fabricated. The apex of nanotips ...
متن کاملOptimization of Electrochemical Etching Parameters in FIM/STM Tungsten Nanotip Fabrication
Field Ion Microscopy (FIM) and Scanning Tunneling Microscopy (STM) have found a wide application in nanotechnology. These microscopes use a metallic nanotip for image acquisition. Resolution of FIM and STM images depends largely on the radius of nanotip apex; the smaller the radius the higher the resolution. In this research, for tungsten nanotip fabrication, electrochemical etching of tungsten...
متن کاملElectrolyte-free Amperometric Immunosensor using a Dendritic Nanotip.
Electric detection using a nanocomponent may lead to platforms for rapid and simple biosensing. Sensors composed of nanotips or nanodots have been described for highly sensitive amperometry enabled by confined geometry. However, both fabrication and use of nanostructured sensors remain challenging. This paper describes a dendritic nanotip used as an amperometric biosensor for highly sensitive d...
متن کاملElectron beam collimation with a 40000 tip metallic double-gate field emitter array and in-situ control of nanotip sharpness distribution
The generation of highly collimated electron beams from a double-gate field emitter array with 40000 metallic tips and large collimation gate apertures is reported. Field emission beam measurements demonstrated the reduction of the beam envelope down to the array size by applying a negative potential to the on-chip gate electrode for the collimation of individual field emission beamlets. Owing ...
متن کاملNanotip electron gun for the scanning electron microscope.
Experimental nanotips have shown significant improvement in the resolution performance of a cold field emission scanning electron microscope (SEM). Nanotip electron sources are very sharp electron emitter tips used as a replacement for the conventional tungsten field emission (FE) electron sources. Nanotips offer higher brightness and smaller electron source size. An electron microscope equippe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nanotechnology
دوره 17 22 شماره
صفحات -
تاریخ انتشار 2006