Detection of Harmonic Pollution Ranking of Non-linear Load in the Hormozgan Distribution Power System by Using New Power Quality Index

نویسندگان

  • Mohammad Keivanfard
  • Gholamreza Nemati
چکیده

In this paper ranking of harmonic distortion of each nonlinear load like economical, ministerial, residential and others include hotels, hospitals, universities and terminals in the HORMOZGAN Province Electrical power Distribution network is determined by using new power quality index which is directly related on harmonic distortion sources in the distribution power system. Then, the ranking of distortion power for each non-linear load, which has adverse effect on entire system, is determined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Procedure for Determining Current Harmonic Contribution around an Operation Point at PCC Using Load Modelling Based on Crossed Frequency Admittance Matrix

Abstract:Today, one of the important issues of power quality (PQ) in power systems is the current harmonics. Increasing expansion of nonlinear loads at different parts of the electric network makes harmonic distortion flow through the network. This causes the network to have background voltage and current harmonic distortion and even affect on the PQ of linear load performance. Therefore, it is...

متن کامل

A Coordinated Control Scheme for Improving Voltage Quality Using Power Electronics Interfaced DGs

Recently, increasing of non-linear loads in the power distribution network has been increased harmonics in these networks. The harmonics problems get worse and complicated by installation of power factor correction capacitors and filters. But the Distributed Generations (DGs) interface inverters with properly control can help to improve power quality, harmonic compensation and voltage unbalance...

متن کامل

An Intelligent Method Based on WNN for Estimating Voltage Harmonic Waveforms of Non-monitored Sensitive Loads in Distribution Network

An intelligent method based on wavelet neural network (WNN) is presented in this study to estimate voltage harmonic distortion waveforms at a non-monitored sensitive load. Voltage harmonics are considered as the main type of waveform distortion in the power quality approach. To detect and analyze voltage harmonics, it is not economical to install power quality monitors (PQMs) at all buses. The ...

متن کامل

Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method

This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...

متن کامل

Capacitor Placement in Distorted Distribution Network Subject to Wind and Load Uncertainty

Utilizing capacitor banks is very conventional in distribution network in order for local compensation of reactive power. This will be more important considering uncertainties including wind generation and loads uncertainty. Harmonics and non-linear loads are other challenges in power system which complicates the capacitor placement problem. Thus, uncertainty and network harmonics have been con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013