Treating the right patient at the right time: access to cardiovascular nuclear imaging.

نویسندگان

  • K Y Gulenchyn
  • A J McEwan
  • M Freeman
  • M Kiess
  • B J O'Neill
  • R S Beanlands
چکیده

Cardiovascular nuclear medicine uses agents labelled with radioisotopes that can be imaged with cameras (single-photon emission tomography [SPECT] or positron emission tomography [PET]) capable of detecting gamma photons to show physiological parameters such as myocardial perfusion, myocardial viability or ventricular function. There is a growing body of literature providing guidelines for the appropriate use of these techniques, but there are little data regarding the appropriate timeframe during which the procedures should be accessed. An expert working group composed of cardiologists and nuclear medicine specialists conducted an Internet search to identify current wait times and recommendations for wait times for a number of cardiac diagnostic tools and procedures, including cardiac catheterization and angioplasty, bypass grafting and vascular surgery. These data were used to estimate appropriate wait times for cardiovascular nuclear medicine procedures. The estimated times were compared with current wait times in each province. Wait time benchmarks were developed for the following: myocardial perfusion with either exercise or pharmacological stress and SPECT or PET imaging; myocardial viability assessment with either fluorodeoxyglucose SPECT or PET imaging, or thallium-201 SPECT imaging; and radionuclide angiography. Emergent, urgent and nonurgent indications were defined for each clinical examination. In each case, appropriate wait time benchmarks were defined as within 24 h for emergent indications, within three days for urgent indications and within 14 days for nonurgent indications. Substantial variability was noted from province to province with respect to access for these procedures. For myocardial perfusion imaging, mean emergent/urgent wait times varied from four to 24 days, and mean nonurgent wait times varied from 15 to 158 days. Only Ontario provided limited access to viability assessment, with fluorodeoxyglucose available in one centre. Mean emergent/urgent wait times for access to viability assessment with thallium-201 SPECT imaging varied from three to eight days, with the exception of Newfoundland, where an emergent/urgent assessment was not available; mean nonurgent wait times varied from seven to 85 days. Finally, for radionuclide angiography, mean emergent/urgent wait times varied from two to 20 days, and nonurgent wait times varied from eight to 36 days. Again, Newfoundland centres were unable to provide emergent/urgent access. The publication of these data and proposed wait times as national targets is a step toward the validation of these recommendations through consultation with clinicians caring for cardiac patients across Canada.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

متن کامل

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

Clinical significance of additional lateral imaging in diagnosis of prosthesis infection by combined Tc-99m labeled leukocyte/bone marrow scintigraphy

Introduction: Recently the most accurate diagnostic method in the diagnosis of prosthesis infection is the combination of Tc-99m labeled leukocyte/bone marrow imaging. However the diagnostic efficiency of the test is influenced because of its low spatial resolution. Recently SPECT/CT imaging is implicated in this test with efficient additional diagnostic improvement. In the dep...

متن کامل

FDG-PET/CT and CT findings of a benign solitary fibrous tumor of the kidney: correlation with pathology

Herein, we report the F-18 fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) findings of a benign solitary fibrous tumor (SFT) of the kidney. The patient was a 63-year-old woman with a mass in the right kidney (10×9.7 cm), incidentally found on CT images. The CT scan showed a lobulated tumor arising from the hilum of the right kidney. The tumor consisted o...

متن کامل

Myocardial damage of the entire ventricular region in a patient with acute myocardial infarction

Technetium-99m-pyrophosphate (99mTc-PYP) has been used, in combination with thallium-201, to estimate the site and extent of myocardial infarcts. We report a case of acute myocardial infarction with severe coronary disease in which the distribution of 99mTc-PYP was extensive. A 78-year-old man presented with dyspnea, and a diagnosis of non-ST-segment elevation acute myocar...

متن کامل

Bone imaging demonstration of osseous lesions and hepatic uptake: Amyloid and renal dialysis effect

A 64-year-old woman, with amyloid related kidney failure (On renal dialysis) had a bone scan because of pain in the right upper femur. The 99m Tc-MDP images revealed marked hepatic uptake. In addition, there was right proximal femoral concentration of radiotracer, which corresponded to a fracture site. As an added finding, the same femor demonstrated circumferential uptake at the lower po...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Canadian journal of cardiology

دوره 22 10  شماره 

صفحات  -

تاریخ انتشار 2006