Parameter estimation and rate model simulation of partial breakthrough of bovine serum albumin on a column packed with large Q Sepharose anion-exchange particles

نویسندگان

  • Tingyue Gu
  • Ganesh Iyer
  • Kwok-Shun C. Cheng
چکیده

This work presents a systematic procedure for using the general rate model to predict experimental chromatograms. The model considered axial dispersion, interfacial film mass transfer and intraparticle diffusion with parameters that have been intensively investigated in classical chemical engineering masstransfer research. Theoretical equations, mass-transfer correlations and experimental procedures for obtaining bed voidage, particle porosity, mass-transfer parameters and Langmuir isotherm parameters are described. Three simple experiments were used to obtain system delay volume, bed voidage and particle porosity, respectively. Mass-transfer parameters were estimated using existing correlations in the literature without the need for additional experiments. A complete example was used to illustrate the approach. The model satisfactorily predicted the partial breakthrough curve of bovine serum albumin on a chromatography column packed with large anion-exchange particles with a nominal diameter of 90 lm. A parameter sensitivity analysis indicated the importance of accurate intraparticle diffusion modeling and demonstrated that lumped-particle models would be inadequate for understanding chromatographic behavior of large particles. 2013 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Dynamic Binding Capacity of Anion Exchange Chromatography Media for Recombinant Erythropoietin Purification

  Background:The dynamic binding capacity (DBC) of a chromatography matrix in protein purification is the amount of the total protein absorbed into the matrix, before occurrence of a significant break in the breakthrough curve. Optimization of the process criteria for maximum DBC avoids extra process scale-up and reduces ...

متن کامل

Chromatographic Characterization and Process Performance of Column-Packed Anion Exchange Fibrous Adsorbents for High Throughput and High Capacity Bioseparations

Fibrous materials are prominent among novel chromatographic supports for the separation and purification of biomolecules. In this work, strong anion exchange, quaternary ammonium (Q) functional fibrous adsorbents were evaluated with regards to their physical and functional characteristics. A column packed with Q fibrous adsorbent illustrated the good column packing efficiency of theoretical pla...

متن کامل

Ion Exchange Column Performance Model for Separation of Zr(IV) and Hf(IV) in Elution Process

A mathematical model of sorption of Zirconium and Hafnium cations mixture and elution of these ions from a cation exchange resin bed is developed. Sulfuric acid is selected as the eluent for selective separation of Zr and Hf in a packed bed of Dowex cation exchange resin. The column model is a dispersed plug flow model,and assumed to consist of randomly packed synthetic and spherical resin ...

متن کامل

Application of Magnetic Polymer Particles Modified with β–Cyclodextrin for Adsorption of Bovine Serum Albumin

Magnetic polymer particles which were modified by vinyl groups and subjected topolymerization by vinyl β-Cyclodextrin derivative, has been used as adsorbent for sorption andrelease of bovine serum albumin and the equilibrium and kinetics of the adsorption process werestudied. The absorbability and releasing of this protein through the new polymer has beenmeasured by ultraviolet-visible spectros...

متن کامل

Mathematical Modeling of Fixed Bed Adsorption: Influence of Main Parameters on Breakthrough Curve

Dynamic modeling and simulation of fixed bed adsorption process was carried out by explaining the behavior of breakthrough curve parameter. Adsorption of sulfur compound, present in road fuel, has posed a great challenge. A model of fixed bed adsorption of benzothiophene from fuel was formulated with non-ideal plug flow behavior and considered velocity variation along a column. The model was so...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013