PC-based Motion Control in a superconducting electron linear accelerator

نویسنده

  • Suren Karabekyan
چکیده

An exciting new research facility is currently under construction in the Hamburg metropolitan region. Opening in 2017, the center will house the European XFEL X-ray laser, an apparatus generating ultra-short X-ray flashes – 27,000 times per second – with a brilliance that is a billion times higher than that of current conventional X-ray radiation sources. PC-based control and drive technology from Beckhoff is used to position a total of 91 special high-precision magnet assemblies (undulators) of the underlying electron accelerator. The European XFEL X-ray laser is installed in a

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy

Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...

متن کامل

New Simulation Results for the S-dalinac Electron Source

For the operation of its mid-infrared FEL the superconducting electron accelerator S-DALINAC has to produce bunches with a charge of 6 pC and a duration of 2 ps FWHM. In order to achieve these figures a subharmonic injection scheme was added to the 3 GHz cw accelerator. The electron gun consists of a grid controlled thermionic cathode on a 250 kV terminal. It produces electron pulses with a cha...

متن کامل

Digital RF Control System for the Pulsed Superconducting Linear Accelerator

The FLASH (Free Electron Laser in Hamburg) (Ackermann et al., 2007) is a user facility providing high brilliant laser light for experiments. It is also a unique facility for testing the superconducting accelerator technology for the European XFEL (Weise, 2004) and the International Linear Collider (Ross et al., 2011). The LLRF (low level RF) system is used to maintain the beam stabilities by st...

متن کامل

Proposal for a 1⁄2 Mw Electron Linac for Rare Isotope and Materials Science

TRIUMF, in collaboration with university partners, proposes to construct a megawatt-class electron linear accelerator [1] (e-linac) as a driver for U(γ,f) with rates up to 10−10 fissions/sec, and for Be(γ,p)Li for materials science. The emphasis would be on neutron-rich species. The 50 MeV, 10 mA, c.w. linac is based on superconducting radiofrequency technology at 1.3 GHz. Though high power/cur...

متن کامل

A Compact Soft X-ray Free-Electron Laser Facility based on a Dielectric Wakefield Accelerator

X-ray free-electron lasers (FELs) are expensive instruments with the accelerator holding the largest portion of the cost of the entire facility. Using a highenergy gain dielectric wakefield accelerator (DWA) instead of the conventional accelerator may reduce the facility size and, significantly, its cost. We show that a collinear dielectric wakefield accelerator can, in principle, accelerate lo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015